一项案例研究,对比了尸体探测犬与电子鼻技术在探测秘密坟墓方面的能力。 机翻

A case study comparing the detection ability of cadaver detection dogs and electronic nose technology to a clandestine grave.

自动标签待生成
期刊PloS one
发表日期2026-10-21
物种犬
DOI10.1371/journal.pone.0360233
PMID42905671

摘要

Cadaver detection dogs (CDDs) are one of the best tools to locate clandestinely buried human remains. However, large data gaps exist in what VOC classes and concentrations are targeted by CDDs for detection. This study compared the alert responses produced by CDDs used by the New South Wales Police Force to responses generated by an electronic nose (named the NOS.E) with metal oxide sensors to a clandestine burial. For confirmatory analysis, VOC samples of the clandestine burial were taken, and compounds were identified using GC × GC-TOFMS. While statistical work was limited due to sample sizes, inferences were made about VOC presence and concentration to NOS.E and detection dog ability. Both CDDs and NOS.E were able to detect targeted chemical classes (sulfur and nitrogen containing compounds, alcohols, alkanes and aldehydes) which was supported by GC × GC-TOFMS. Correlation analyses demonstrated non-significant, but observational patterns that CDDs true positive alerts were associated with higher NOS.E responses to sulfur and nitrogen containing compounds, alcohols and alkanes. Additionally, a "no alert" or "False Positive" alert was associated with lower NOS.E responses. This work supports that it is both the presence and abundance of VOC chemical classes that influence true positive alerts from CDDs to buried human remains.

站内已收录开放获取全文,见下方。

全文 开放获取 · Open Access (cc-by, via Unpaywall) 中文机翻

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 1 / 17

开放获取 引用格式:Brown AO, Alahakone S, Lamb E, Pasin D, Hawker D, Liu T, 等 (2026) 一项比较尸体搜寻犬与电子鼻技术对隐蔽墓穴检测能力的案例研究。PLoS One 21(10): e0360233. https://doi.org/10.1371/journal.pone.0360233 编辑:Xiaoen Wei,上海中医药大学附属曙光医院,中国 收稿日期:2026年6月3日 接受日期:2026年9月24日 发表日期:2026年10月21日 版权:© 2026 Brown 等。这是一篇开放获取文章,依据 Creative Commons Attribution License 条款发布,允许在任何媒介上无限制使用、分发和复制,前提是保留原作者和来源。数据可用性声明:NOS.E 数据集及配套代码可在 github.com/Taphonomic-Analytical-Forensics/nose-dogs 获取。研究论文 一项比较尸体搜寻犬与电子鼻技术对隐蔽墓穴检测能力的案例研究 Amber O. Brown 1,2, Sandali Alahakone 1, Erin Lamb 1, Daniel Pasin 3, Darryl Hawker 4, Taoping Liu 5, Wentian Zhang 6, Shari L. Forbes 7, Steven Su 8, Maiken Ueland 1,6 * 1 悉尼科技大学数学与物理科学学院法医学中心,澳大利亚新南威尔士州悉尼,2 北佛罗里达大学,美国佛罗里达州杰克逊维尔,3 Hyperion Data,澳大利亚新南威尔士州格里菲斯,4 新南威尔士州警察部队警犬队,澳大利亚新南威尔士州帕拉马塔,5 西安电子科技大学信息力学与传感工程学院,中国西安,6 悉尼科技大学数学与物理科学学院,澳大利亚新南威尔士州悉尼,7 温莎大学化学与生物化学系,加拿大安大略省温莎,8 山东第一医科大学医学信息与人工智能学院,中国山东省济南 * maiken.ueland@uts.edu.au 摘要 尸体搜寻犬(CDDs)是定位隐蔽埋藏人类遗骸的最佳工具之一。然而,关于CDDs用于检测时所针对的VOC类别和浓度,仍存在大量数据空白。本研究比较了新南威尔士州警察部队使用的CDDs对一处隐蔽埋葬点产生的示警反应与配备金属氧化物传感器的电子鼻(名为NOS.E)所产生的反应。为进行验证分析,采集了该隐蔽埋葬点的VOC样本,并使用GC × GC-TOFMS对化合物进行了鉴定。尽管由于样本量限制,统计工作有限,但仍就VOC的存在与浓度对NOS.E和检测犬能力的影响作出了推断。CDDs和NOS.E均能够检测到目标化学类别(含硫和含氮化合物、醇类、烷烃和醛类),这得到了GC × GC-TOFMS的支持。相关性分析显示了非显著但可观察的模式,即CDDs的真阳性示警与NOS.E对含硫和含氮化合物、醇类和烷烃的较高响应相关。此外,“未示警”或“假阳性”示警与较低的NOS.E响应相关。本研究支持以下观点:VOC化学类别的存在和丰度均会影响CDDs对埋藏人类遗骸的真阳性示警。1. 引言 定位长期失踪人员(失踪超过三个月)[1]是执法部门面临的一些资源最为密集且最具挑战性的障碍。

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 2 / 17 每一起失踪人口调查的第一步都是在最后目击到该对象的地点周围开展实地搜寻。如果担心失踪者已经死亡,执法部门将采用发现和回收人体遗骸的方法。当尸体暴露于自然环境中或被遗弃在户外时,由于环境变化或动物活动,遗骸可能变得散落或被掩埋。然而,当尸体被意图掩盖犯罪证据的人故意处置时,遗骸可能被埋藏在沉积物中的不同深度[2]。这类受害者的搜寻回收工作可能颇具挑战性,因为依赖目视定位遗骸的方法(如地面或空中搜寻)往往难以奏效,可能需要额外方法(如检测腐败气味)来定位和回收。目前,寻尸犬(CDDs)是定位被环境因素(即土壤、水和植被)遮蔽的人体遗骸的最佳工具之一。寻尸犬具有卓越的嗅觉系统[3–5],并经过训练能够检测分解过程中大分子(如蛋白质、脂质和碳水化合物)分解所产生和释放的特定挥发性有机化合物(VOCs)[6–8]。VOCs具有高蒸气压和低分子量,能够持续释放到环境中[9,10],既可通过受害者内源性产生,也可来自其香水、乳液或保健产品的外源性来源[11]。VOCs从高浓度区域(即“源头”)向低浓度区域扩散。由于这些VOCs从源头持续扩散,会形成“气味锥”,其中VOCs在目标正上方的空气中浓度更高,并因风等环境因素而从源头向外稀释[3]。因此,寻尸犬能够从气味锥边缘检测到痕量VOCs,并循气味追踪至VOCs浓度最高的区域[3,8,12–14]。一旦寻尸犬定位到目标,它们会通过训练过的行为或信号向训导员示警。对于被掩埋的遗骸,寻尸犬对气味锥的检测变得复杂,因为土壤成分和含水量起到吸收汇的作用,截留VOCs并影响气味锥的扩散[15,16]。迄今为止,关于从气味锥扩散的VOCs类型和浓度的定量知识仍然有限。每种VOC的扩散速率因其特定化学特性(如大小、极性、稳定性和反应性)以及扩散时的环境条件而异。此外,目前尚不清楚扩散如何影响气味锥中VOCs谱相对于其源头的变化(即不完整的分解谱),以及稀释或不完整的分解谱如何影响寻尸犬的效能。目前用于鉴定和定量分解人体遗骸所产生VOCs的方法依赖于实验室分析技术[10,15,17–21],不过近期研究已探索利用电子鼻(e-noses)实时检测与人体分解相关VOCs的潜力[22–24]。此外,电子鼻还可用于深入了解寻尸犬的检测能力并辅助训练。在这些情况下,电子鼻可在训练期间部署,以减少寻尸犬的假阳性(无目标时反应)和假阴性(对目标无反应)示警。资助:MU获得澳大利亚研究理事会探索早期职业研究奖(DE210100494)资助。资助方在研究设计、数据收集与分析、发表决定或稿件准备中均无任何作用。利益冲突:作者声明不存在任何利益冲突。

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 3 / 17 电子鼻是便携式或半便携式设备,利用多传感器(如MOX)阵列模拟哺乳动物的嗅觉。当传感器接触目标挥发性有机化合物(VOCs)时,传感器的电阻降低,电流电压升高,产生受特定VOC类别浓度影响的定量信号。在室外环境中,传感器的基线响应受到自然含有环境VOCs的参考空气的影响。为了记录警报,目标VOCs的浓度必须高于环境中的浓度[23]。对于将电子鼻用于检测人类遗骸的场景,必须谨慎选择MOX传感器,因为目标化学类别的流行率和丰度在分解过程(即“阶段”)中会发生变化。为实现稳健检测,应优先选择针对含氮化合物、含硫化合物以及醇类和醛类的传感器,因为这些物质存在于人类分解的所有阶段[25]。迄今为止,尚无标准化方法来训练和分析尸体探测犬(CDDs)在真实场景中的准确性[7,12,26,27]。此外,关于CDDs检测能力的数据明显缺乏,包括检测限以及与CDD效率和准确性相关的定量分析数据。例如,尚不清楚是特定VOCs的存在还是浓度触发CDD警报。尽管多年来对分解VOCs的形成和释放进行了研究,并确定了不同分解阶段释放的VOCs,但关于CDDs在特定时间段内针对哪些特定VOCs来定位死者的信息很少。目前尚不清楚是针对单一VOCs、组合VOC谱,还是追踪特定VOCs或VOC类别的相对浓度,并导致CDD真阳性警报。这些信息的缺乏使CDDs的训练和评估复杂化,并降低了CDD在法庭环境中的证据能力[28]。CDD训练和搜索活动及相关资源可通过电子鼻技术的二次确认来加强,以提供分析支持。本研究旨在比较NOS.E(悉尼科技大学(UTS)内部开发的电子鼻)对隐蔽墓葬定位时新南威尔士州警察部队(NSWPF)使用的CDDs警报的响应。具体而言,研究设置使得电子鼻的响应可与三只认证CDDs对单一埋葬死者的响应进行比较。为进行分析确认(即识别来自埋葬遗骸的化学类别),采集埋葬遗骸的顶空气体并通过GC × GC-TOFMS进行分析(S1图)。试验设置模拟长期失踪人员场景,即尸体被埋葬约三个月。2. 材料与方法 2.1 实验地点 研究在西悉尼新南威尔士州澳大利亚埋藏学实验研究设施(AFTER)进行。该设施占地约4.86公顷的坎伯兰干燥硬叶林,归UTS所有,并符合所有伦理和法律要求以进行人类尸体研究(UTS HREC参考编号ETH18–2999)。供体通过UTS遗体捐献计划获得,由外科和解剖科学设施(SASF)管理。根据新南威尔士州《解剖法》(1977年),所有供体均同意将其遗骸用于AFTER的研究目的。供体为男性,79岁,死亡时体重75.2 kg(2020年3月20日)。放置前,尸体储存在冷藏设施中。2020年3月25日,供体(未着衣)以仰卧位放置在约60 cm深的墓穴中。该墓穴位于设施内距任何其他人类遗骸200 m以上的位置。初次放置后,墓穴保持不受干扰98天,然后开始采样,以模拟长期隐蔽墓穴,从而符合长期失踪人员的定义(即超过三个月)[1]。墓穴被划分为6个区域:R1、R2、R3、R4、R5和R6(图1)。在探测墓穴的场合(除第98天初次搜索外的所有日子),在墓穴内约20–30 cm深处探测14个位置(图1),以允许空气逸出。作为质量控制,并确保CDDs不会对扰动土壤的视觉线索而非分解VOCs发出警报,三个空对照墓穴被

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 4 / 17 此外,在捐赠者下葬当天也制备了样本,并采用与人体墓穴相同的方式进行探测。选取一座空墓作为化学分析(GC × GC-TOFMS 和 NOS.E)的对照。使用配备 Hobo U30 无远程通信数据记录仪(OneTemp pty ltd. 澳大利亚)的 Hobo 气象站,以每小时一次的频率监测温度(°C)、太阳辐射(W/m²)、相对湿度(%)、风速(m/s)、风向和降雨量(mm)。上述环境参数均与每次试验中探测前和探测后两种情景下的 NOS.E 响应进行了相关性评估。2.2 尸体探测犬 本研究开展时,使用了三只经新南威尔士州警察部队(NSWPF)警犬队认证的尸体探测犬(CDD)(表1)。这些犬此前已接受过针对人体骨骼、分解液及分解液污染衣物的训练。在整个研究过程中,由于 CDD 及其训导员的工作任务安排,每个采样日到场的犬只数量有所不同。本试验设计为单盲研究,因为使用同一墓穴进行双盲研究不可行,且会取消所需的训导员专家监督,从而导致犬只反应记录出现困难。研究设计遵循 NSWPF 警犬队的标准训练方案。在本工作中,使用了三只独立的 CDD 及三名各自的训导员,在第一次试验中对埋藏遗体的位置均不知情。在每次试验运行中,每只 CDD 均独立进行搜索,不受训导员引导。主训练员对墓穴位置知情,并从远处监督 CDD 的探测反应,以判定是否出现明确的示警。当 CDD 进入已知的墓穴 GPS 位置并有机会示警时,记录示警。示警定义为:“真阳性”,即 CDD 对 NOS.E 传感器响应高于基线的区域示警;“真阴性”,即 CDD 对 NOS.E 传感器响应未高于基线的区域未示警;“假阳性”,即 CDD 对 NOS.E 传感器响应未高于基线的区域示警;“假阴性”,即 CDD 对 NOS.E 传感器响应高于基线的区域未示警。所有示警(“真阳性”、“真阴性”、“假阳性”和“假阴性”)均在主训练员专家意见确认以及 NOS.E 信号响应高于基线的确认性结果后记录。犬只评估在获得动物伦理批准(ETH20–5205)后进行。在搜索活动中,每只犬沿周边被带入场地(不同次访视的起始位置不同),远离场地内任何现有捐赠者,在距墓穴约 150 m 处解开牵引绳释放,并允许其对该区域进行大范围搜索。如果犬只能够按照其训练正确找到墓穴,则用网球(游戏奖励)予以奖励。随着采样周数增加,CDD 有可能逐渐熟悉 图1. 墓穴场地区域及探测点编号示意图。在死后 98、105、120、126、147 和 161 天,使用 CDD 和 NOS.E 进行了六个独立的搜索日。https://doi.org/10.1371/journal.pone.0360233.g001

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 5 / 17 与墓穴的面积和位置有关。因此,为防止假阳性警报,每次采样时犬只均从不同方向脱绳释放。若一次采样期间有多只犬在场,则存在一种担忧:尸体探测犬可能识别到另一只犬在墓穴上方留下的气味,从而产生假阳性警报。为应对此问题,训导员会在每只犬完成搜索后引导其经过三个对照墓穴各一次,以确保尸体探测犬的气味不会集中于某一位置。每次采样时犬只的搜索顺序也随机化,且第一只犬与后续犬只的搜索之间设有休息间隔。选择三个对照墓穴以减少尸体探测犬的偏差,但为节省资源,仅选择一个对照墓穴进行实验室分析评估。2.3 电子鼻(NOS.E)采样 本研究使用的电子鼻(NOS.E)由悉尼科技大学法医科学中心与悉尼科技大学生物医学工程学院合作开发。基于既往人体分解研究[22,25,29–34],共选择并配置了5个氧化锡气体传感器(TGS)金属氧化物(MOX;Figaro,日本)气体传感器(表2)。这些传感器是专门针对人体分解挥发性有机化合物(VOCs)而选择的,NOS.E中所配置传感器的检测限此前已确定[24]。本研究选择的传感器靶向醇类(传感器1、2)和烷烃类(传感器1–3)以及含氮和含硫化合物(传感器4、5)。由于室外环境的变异性,未评估传感器检测限。然而,通过基线评估和建立峰值评估的阈值标准,已处理了正负交叉反应性和VOC抑制问题[22]。采样前,将NOS.E开机并使其对环境进行环境采样20分钟,以确定传感器对环境的基线响应。NOS.E采样在犬只采样试验之前进行,空气进气速率恒定于最大容量(约1.1 L/min),与既往研究一致[22,24]。采样以连续方式进行,同时使NOS.E进气系统在墓穴上方约15 cm高度悬移,按数字方向从R1移至R6(1–13;图1)。选择预设路径以确保各采样日之间的一致性,并确保覆盖所有墓穴区域。任何传感器响应均记录为时间标记,响应位置则转记于墓穴地图上(图1)。每次试验日还对距实验墓穴5 m处的对照墓穴进行采样,以比较NOS.E传感器响应。此外还记录了一般场地区域的环境响应,以确保任何VOC的存在并非源于环境。表1. 研究时评估的每只尸体探测犬相关的生物学和训练信息摘要。编号 年龄(岁)品种 研究时经验(年)参与试验次数 犬1 3 英国史宾格犬 约1 1/6 犬2 4 拉布拉多寻回犬 约2 4/6 犬3 7.5 英国史宾格犬 约6 4/6 https://doi.org/10.1371/journal.pone.0360233.t001 表2. NOS.E传感器配置。传感器 传感器名称 目标气体 1 TGS 2610 5U 醇类/烷烃类 2 TGS 2600 醇类/烷烃类 3 TGS 2612 5U 烷烃类 4 TGS 2603 硫/氮 5 TGS 2602 氮/硫 https://doi.org/10.1371/journal.pone.0360233.t002

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 6 / 17 NOS.E数据记录是通过在坟墓上方行走以模拟搜索事件而连续采集的。当观察到任何传感器的响应高于基线时,将采样喷嘴保持静止,直至最大传感器响应保持恒定。该事件随后被记录为一次“命中”。在“命中”之后,将进气系统移离目标,并让传感器恢复至基线,然后再继续对剩余坟墓区域进行采样。NOS.E采样方案包括在每次采样事件之间进行一系列冲洗步骤,以消除残留或交叉污染(表3)。每个序列采用200秒的主动VOC采样时间,并在数据处理过程中拼接在一起以覆盖整个坟墓区域。2.4 NOS.E数据处理 NOS.E(.txt)文件使用改编自Brown等人[22]的峰值检测算法进行处理,以适应同一文件内的多次命中。该算法旨在实现峰高的自动化计算。所有检测到的峰均由作者审核,以确定其有效性并纳入进一步分析。该算法使用Python 3.7.12、pandas(1.3.5)[35]、scipy(1.7.3)[36]和peakutils(1.3.5)[37]开发,数据可视化使用matplotlib(3.5.3)[38]和seaborn(0.12.2)[39]。代码、NOS.E数据文件和输出文件可在github.com/Taphonomic-Analytical-Forensics/nose-dogs获取。简言之,使用scipy.find_peaks函数自动检测峰(及命中),突出度值设为0.025。该值是基于对所得峰值命中的手动评估而选择的,以确保没有假阴性读数。归一化峰高通过从峰值最大值中减去基线(使用peakutils.baseline函数以默认参数确定)来确定。对于最大与最小传感器响应之差小于最小响应5%的传感器,或使用峰值检测算法未检测到峰的传感器,峰高设为零。峰还在各数据文件之间进行对齐,以与CDD的命中相关联。为纳入环境数据,将.csv文件导入Python并整合到NOS.E探测前后图的可视化中。显示所有五个传感器剖面及计算峰高的采样运行示例见补充信息中的S2图。NOS.E传感器响应(传感器2–5;传感器1因仅有一个数据点而被排除)使用箱线图和 violin 图与CDD警报类型进行视觉比较。样本量小且变量多的组合使该数据集的统计功效较低,限制了严格的统计分析。选择Spearman秩相关(ρ)作为研究性方法,将NOS.E传感器响应与警报类型进行比较。选择该方法是因为它更适合本数据集中所观察到的非正态分布、非线性且单调的小样本数据。缺失的传感器值使用k近邻(kNN)插补法进行插补,其中(k = 5)。此外,为确定在多次检验事件下是否存在统计学显著性,特别是由于样本量小,对p值应用了Benjamini-Hochberg(B-H)错误发现率(FDR)校正。表3. VOC采样期间NOS.E采样指标。腔室冲洗I 100秒 真空时间I 10秒 基线设置20秒 真空时间II 10秒 采样时间200秒 基线恢复100秒 腔室冲洗II 100秒 https://doi.org/10.1371/journal.pone.0360233.t003

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 7 / 17 2.5 GC × GC-TOFMS样品采集 用于实验室分析的VOC样品与犬试验及NOS.E采样日同步采集。除第98天外,所有样品均在探查后采集。从试验墓穴和对照墓穴的顶空各采集三份重复样品。在每个墓穴上方放置一个大铝制罩,放置20分钟以使VOC积累,随后将其采集到装有Tenax TA和Carbograph 5TD的双吸附管中(Markes International Ltd.,英国;部件号C2-AAXX-5149)。使用ACTI-VOC™低流量泵(Markes International Ltd.,英国)以100 mL/min的速率主动采样VOC 10分钟,共采集1 L顶空气体。随后将每根管用铝箔包裹,置于气密罐中运送至实验室进行分析。样品分析前,使用eVol® XR手持式自动分析注射器(SGE Analytical Science,悉尼,澳大利亚)向每根吸附管注入0.2 μL溶于甲醇的10 ppm溴苯作为内标(Sigma-Aldrich,悉尼,澳大利亚)。2.6 GC × GC-TOFMS分析 每根吸附管使用Markes Unity 2热脱附仪(Markes International, Ltd,美国)和Series 2 ULTRA多管自动进样器(Markes International, Ltd,美国)进行热脱附(TD)。每根管在300°C下脱附4分钟,然后以25 mL/min的流速转移至保持在−15°C的通用冷阱(TenaxTA/Carbograph 1TD)。冷阱脱附在300°C下进行4分钟,流速为25 mL/min。样品分析使用Pegasus 4D GC × GC-TOFMS(LECO,Castle Hill,NSW,澳大利亚)进行,该仪器通过一根加热至120°C的1 m无涂层熔融石英传输线(Markes International Ltd.)与TD单元连接。TD传输线使用Ultimate Union套件(Agilent Technologies,Mulgrave,VIC,澳大利亚)与主柱连接。主柱为Rxi®-624Sil MS(30m x 0.250 mm内径,1.40 μm膜厚),次级柱为Stabilwax®(2m x 0.250 mm内径,0.5μm膜厚)(Restek Corporation,悉尼,NSW,澳大利亚)。使用SilTite TM

μ-Union(SGE Analytical Science,Ringwood,VIC,澳大利亚)连接主柱和次级柱。氦气用作系统载气,保持恒定流速1.0 mL/min。主炉在35°C下保持5分钟,然后以5°C/min的速率升至240°C,再在240°C下保持5分钟,总运行时间为51分钟。调制器偏移设为5°C,次级炉温偏移为15°C,调制周期为5秒。质谱仪传输线保持在250°C,质量采集范围为29–450amu,采集速率为100谱/秒。离子源温度保持在200°C,电子电离能量为−70 eV,检测器电压偏移为200 V。2.7 GC × GC-TOFMS数据处理 数据处理使用ChromaTOF®软件(版本4.51.6.0,LECO,澳大利亚)进行。基线跟踪以80%偏移和自动基线平滑进行,信噪比为150。第一维使用30秒峰宽,第二维使用0.15秒峰宽。使用美国国家标准与技术研究院(NIST,2011)质谱库,最低库匹配因子为80%以建立化合物列表。为进行跨样品化合物比对,将样品按各自采样日分类。所有对照样品归入同一类。由于分解过程预期采样日之间存在固有差异,分析物须在某一类中30%的样品中出现或总体上在两份样品中出现方可保留。初始数据处理后,将化合物列表导出至Microsoft Excel,去除已知污染物和仪器伪影(柱流失、溶剂等)。重复样品取平均值,空白扣除使用50%阈值,即实验样品中的分析物须在≥

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 8/17 空白分析物响应的50%[22,31,34]。随后将剩余化合物按其各自的化合物类别(醇、醛、烷烃、烯烃、芳香族、酯、醚、卤代、酮、含氮、含硫或其他)进行分类。数据可视化使用Python 3.7.6结合seaborn(0.11.1)[39]和matplotlib(3.3.4)[38]完成。3. 结果与讨论 3.1 环境数据 搜索试验于埋葬后第98天(2020年7月1日)开始,搜索期间日平均气温范围为9.1–13.7°C,日平均气温为13.4°C(图2)。这反映了澳大利亚(悉尼)冬季的条件,此条件下VOCs的可获得性低于较温暖月份[29,30]。埋葬后第123–125天及第135–143天期间出现了大范围强降雨。3.2 NOS.E数据 对每个采样日的NOS.E结果进行了评估(图3),并分为坟墓探测前和探测后两类。所有采样日均记录了NOS.E响应。被视为阳性响应的“命中”次数和丰度(定义为坟墓采样期间NOS.E传感器产生高于基线信号的次数)在探测后更高。这是预期之中的,因为探测的作用是释放埋葬环境中的VOCs[31],从而使被截留的VOCs可供扩散和检测。传感器2(对应醇类和烷烃)和传感器5(对应氮和硫)在整个试验期间反应最为活跃,是主要响应的传感器。根据先前研究,传感器5对VOCs具有更高的灵敏度,其反应浓度比传感器阵列中所有其他传感器低1.5–2倍[24]。传感器3(烷烃)仅在第126天和第161天发生反应。第161天所有NOS.E传感器均出现响应,这在任何其他采样日均未报告。该日探测阶段,探针意外击中并刺穿了埋葬遗骸。这导致内部截留的VOCs释放,否则这些VOCs不会被检测到。因此,这些传感器响应,尤其是传感器1的响应,很可能不能指示标准搜索场景中存在的VOCs,因为图2. 环境数据,包括日平均气温(°C)和日总降雨量(mm)。https://doi.org/10.1371/journal.pone.0360233.g002

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 9/17 内部VOCs被包含在遗骸内,因此可能不是秘密坟墓检测的主要传感器类型。NOS.E在对照坟墓上方记录到一些传感器响应。该坟墓位于埋葬供体的上风向和上坡方向,距任何其他尸体200米。由于对照坟墓的位置,以及NOS.E采样在犬只试验运行之前进行,这些传感器响应不太可能归因于分解VOC污染。大多数响应来自传感器5,检测含氮和含硫化合物。由于土壤基质是氮循环和硫循环中的汇,传感器响应很可能归因于环境中的氮和硫来源。有趣的是,在探测前,任何评估的环境变量(温度、太阳辐射、相对湿度、风速、风向和降雨量)对NOS.E传感器响应均无明显影响。然而,在探测后场景中,温度与NOS.E传感器响应增加之间可能存在相关性(图3)。样本数量有限,无法对这些观察结果进行统计分析。然而,这一观察结果与先前研究不同,先前研究中NOS.E传感器在检测放置于地面上的人类供体时还受到阵风速度和风向的影响[22]。NOS.E性能差异很可能归因于人类遗骸位置(地表与埋葬)、季节(夏季与冬季)或VOC可获得性(在空气基质中自由可获得与土壤干扰),这些需要进一步测试。3.3 现场搜索结果 按照NSWPF犬只单位的操作方案,每只犬被引导至埋葬供体的下风向,以捕捉气味锥的边缘,并允许其独立搜索秘密坟墓。为尽量减少犬只依赖对坟墓位置的记忆而非利用气味的机会,每个试验日从现场不同区域释放犬只。每只犬通过趴下或吠叫向其训导员示警,以确认其对埋葬遗骸的推定检测。探测事件后,三只犬均在遗骸上躯干上方探测的孔洞处示警(表4;R1和R2)。此后,NOS.E也在该区域以最高传感器读数示警,可能图3. NOS.E传感器响应与采样日温度变化的关系。(a) 表示秘密坟墓探测前采集的数据,(b) 表示探测后采集的数据,(c) 表示从对照坟墓采集的读数。注:第98天未采集探测后数据。https://doi.org/10.1371/journal.pone.0360233.g003

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 10 / 17 由于该区域存在多个正在分解的器官,释放出的挥发性物质的种类和浓度较高[22]。随着采样周数的持续,CDD在区域R1和R2中相同的探测孔处持续发出警报(图1)。在未对坟墓进行重新探测的试验中,三只犬要么未发出警报(犬2和犬3),要么提供了假阳性警报(犬1和犬2)。在对坟墓进行重新探测后,所有犬均能通过阳性警报定位坟墓(表4)。表4. 尸体探测犬警报反应及位置与NOS.E基线以上反应及位置的比较(参见图1)现场情况。N/A表示该犬未参与该采样日的试验。犬试验NOS.E试验日死后探测犬警报警报分类* 警报位置警报位置 D98否犬1N/AN/AN/AN/A 犬2是 真阳性R1,R6部分R2,R6 犬3是 真阳性R2,R6部分 D105否犬1是 假阳性† R1/R2– 犬2N/AN/AN/A 犬3否真阴性– 是犬1是 真阳性R1R2(多次命中),R4,R6 犬2N/AN/AN/A 犬3是 真阳性R3 D120否犬1N/AN/AN/AR3 犬2否真阴性– 犬3N/AN/AN/A 是犬1N/AN/AN/AR3 犬2是 真阳性R3 犬3N/AN/AN/A D126否犬1N/AN/AN/A– 犬2否真阴性– 犬3否真阴性– 是犬1N/AN/AN/AR1(多次命中),R2,R3,R4 犬2是 真阳性R1/R2 犬3是 真阳性R1/R2 D147否犬1N/AN/AN/AR2 犬2N/AN/AN/A 犬3否假阴性– 是犬1N/AN/AN/AR1,R2,R3 犬2N/AN/AN/A 犬3是 真阳性R4 D161否犬1N/AN/AN/A– 犬2是 假阳性† – 犬3N/AN/AN/A 是犬1N/AN/AN/AR1,R2 犬2是 真阳性R2 犬3N/AN/AN/A *相对于NOS.E读数,†向训导员发出警报。https://doi.org/10.1371/journal.pone.0360233.t004

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 11 / 17 NOS.E用于评估是否有化合物释放,或部分图谱是否导致假阳性警报。在采样第105天,犬1在探测前发出了假阳性警报。NOS.E在探测前未对该区域的目标挥发性物质产生信号(表4)。同样参与试验的犬3在第105天探测前未发出警报。犬3的现场经验显著多于犬1(表1),因为犬1在本研究时仅有一年经验,这很可能导致了假阳性警报。3.4 GC×GC-TOFMS结果 从GC×GC-TOFMS分析中鉴定出的化合物根据官能团分类为化学类别,并按采样日取平均值。鉴定出的VOC类别包括卤代化合物、呋喃类、酯类、醚类、酮类、醛类、醇类、烷烃类、环烷烃类、烯烃类、含氮化合物、含硫化合物和芳香族化合物(S1表)。为便于与NOS.E数据直接比较,本研究仅进一步分析了NOS.E传感器可检测到的化合物类别。所有选定的VOC化合物类别在整个试验期间均被检测到(图4),且在126天观察到平均峰面积丰度增加,并在147天进一步增加。这些结果也得到了NOS.E的支持(图3)。增加可能是由于采样前几天降雨后遗骸的再水化,加之平均温度升高(图2),这会促进分解[40,41],导致VOC产生增加。含氮化合物在第98天和第147天检测到较高数量。含硫化合物也在采样第147天达到峰值。然而,在大多数试验日,醇类和烷烃类是VOC图谱的主要贡献者。有趣的是,传感器5(含氮和含硫化合物)在所有采样日中对所有NOS.E传感器的响应最高,这与VOC数据并不直接吻合。这可能是由于传感器5的灵敏度和响应曲线(即对数响应曲线)所致,如先前报道[24]。含硫化合物 图4. 采样期间秘密埋葬地点VOC丰度以峰面积(n = 3)求和并取平均值。除第98天外,所有天数均对埋葬处进行了探测。注意,仅显示NOS.E传感器可检测到的化合物类别。https://doi.org/10.1371/journal.pone.0360233.g004

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 12 / 17 是分解气味中检测到的最广泛公认的一组化合物[10,17,32,34,42–45]。在本研究中,二甲基二硫醚(DMDS)是观察最为一致的多硫化物(S1表)。几种含氮化合物通常在分解早期阶段被发现[6,46],在各采样日也均有检测到(图4和S1表),但与硫化合物类似,它们在GC × GC-TOFMS分析中的丰度非常低。研究发现醇类在整个研究期间呈增加趋势,并在第147天急剧升高,随后在第161天迅速下降(图4)。烷烃类遵循与醇类相似的趋势,但在第120天丰度出现明显下降。3.5 NOS.E与CDD比较 将NOS.E传感器“命中”与CDD警报反应进行了比较。最有经验的犬(犬3;表4)未出现假阳性警报。此外,假阳性警报仅发生在墓穴未被探测的时间段(表4)。对全部五种传感器反应绘制了小提琴图,以与进行多次试验的CDD之间的警报反应进行比较(图5a和5b)。真阳性命中与传感器类型反应的分布比较表明,一只CDD(图5a)的真阳性警报分布比参与多次试验的CDD(图5b)更宽。此外,一只犬在含硫或含氮化合物浓度较高时警报更为坚决。这可能是个体差异、品种差异(英国史宾格犬与拉布拉多寻回犬)或经验差异(6年与2年)的产物。NOS.E和VOC数据均表明,探测后含硫和含氮化合物丰度的增加可能有助于犬2正确产生真阳性警报。小提琴图表明,传感器2(醇类/烷烃类)、4(硫/氮)和5(氮/硫)的集体反应对于准确检测比传感器1(醇类/烷烃类)和3(烷烃类)更为重要。从观察来看,似乎存在一个将人类遗骸VOC与环境硫区分开的阈值(传感器5(氮/硫)),因为在无警报区域检测到的传感器反应较低。然而,一旦传感器反应超过某一峰值高度,该反应便有助于犬只提供真阳性警报。支持这一点的证据是,犬2的假阳性警报显示传感器5反应与“无警报”相似,但其他传感器反应均不相似。当将所有犬只警报类型(包括犬1;图6和图7)与NOS.E传感器反应进行比较时,这一评估得到进一步支持。看来,VOC浓度类别的存在和阈值共同影响了CDD对埋藏人类遗骸的真阳性警报。图5. 尸体探测犬(CDD)警报的小提琴图,CDD 2(a)和CDD 3(b)。每个采样点代表一次记录的警报。“NoA”代表“无警报”,“TP”代表“真阳性”,“PA”代表“部分警报”,“FP”代表“假阳性”。CDD 3未记录到“FP”数据。https://doi.org/10.1371/journal.pone.0360233.g005

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 13 / 17 对kNN插补后的传感器反应进行Spearman秩(ρ)相关分析,在控制错误发现率(BH校正p值)后,未显示反应类型与NOS.E传感器反应值之间存在任何统计学显著关联。从观察来看,ρ值表明真阳性之间存在正单调关联。图6. 联合尸体探测犬(CDD)对秘密墓穴警报的箱线图。每个采样点代表CDD和NOS.E均发出警报的每个位置(R1-13)所记录的警报。“FP”代表“假阳性”,“NoA”代表“无警报”,“PA”代表“部分警报”,“TP”代表“真阳性”。https://doi.org/10.1371/journal.pone.0360233.g006 图7. kNN插补数据和BH校正后传感器值与尸体探测犬(CDD)警报类型之间的Spearman秩(ρ)相关。 “FP”代表“假阳性”,“NoA”代表“无警报”,“PA”代表“部分警报”,“TP”代表“真阳性”。色块颜色使用发散色阶表示ρ的符号和大小,红色代表正关联,蓝色代表负关联。https://doi.org/10.1371/journal.pone.0360233.g007

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 14 / 17 警报与传感器值,而无警报和假阳性则呈现负相关。即,真阳性警报在所有较高的传感器值下倾向于增加,而无警报和假阳性则随传感器值升高而减少。部分警报对所有传感器呈现混合模式。然而,由于这些值不具有统计学显著性,解释时应谨慎。4. 结论 本研究提供了关于VOC类别和浓度如何影响CDD检测能力(就警报反应而言)的新见解。具体而言,本研究有助于辨别哪些VOC化合物类别与CDD的真反应警报相关,并提供了关于哪些VOC类别和浓度较不可能使CDD在检测埋藏环境中人体遗骸时产生确信反应的见解。在本研究之前,所有CDD均未接触过埋藏的人体遗骸。本研究的局限性在于仅能评估一名捐献者,且与年龄、性别、体重指数及其他环境因素(如土壤成分)相关的VOC变异性无法得到充分或统计学评估。然而,这项试点工作有助于理解CDD在其当前训练方案下所开发的能力,并为未来纳入多名捐献者和更大规模研究的工作奠定了基础。NOS.E对CDD提供了相似的传感器反应,随后分析性VOC数据也支持了这一点。如先前研究所示,含硫和含氮化合物的存在对CDD真阳性警报至关重要。本研究有助于证明含硫和含氮化合物的浓度在真检测中发挥作用。已确定,探查墓穴提高了NOS.E的检测能力(图5),无论是在化合物类别检测方面还是命中强度方面。探查墓穴还提高了经验较少的CDD的检测准确性,探查后无假阳性或假阴性警报(表4)。由于警察和CDD的工作安排,本研究中一些变量不可避免或无法控制。例如,每只犬的现场测试次数不同。尽管采用了交替时间表、试验间隔天数以及交替CDD搜索顺序,CDD仍有可能熟悉墓穴位置。因此,在解释经验较丰富犬只较低的VOC阈值时应谨慎。然而,由于探查后无假阴性警报,这表明CDD警报更可能是由于气味图像的变化而非位置记忆。为进一步支持这一点,同时纳入更多捐献者位点的额外研究将是有益的。此外,为便于现场部署,还需进行额外的法医检测和验证,包括传感器检测限、对不同土壤类型和埋葬深度的反应,以及与混合气味的比较。尽管存在研究局限性,但拥有关于犬只是否及检测到何种人体分解VOC的同步分析数据,对于当前和新的尸体检测犬的进一步训练是有用的。支持信息 S1图。描述研究目标及所比较方法的流程图。(PDF)S2图。探查后第161天墓穴的示例采样运行。红线为计算基线,垂直黑线为从基线到峰最大值的距离。(PDF)S1表。显示实验墓穴每个采样日单独初步鉴定的VOC。此处仅呈现三个或更多采样日出现的VOC。(PDF)

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 15/17 致谢 作者感谢新南威尔士州警察部队警犬队的训导员及其犬只Wags、Tilly和Bryson参与了本研究。他们的时间和经验对本项工作极为宝贵。作者还要感谢我们的捐赠者,他们在死后无私地捐献了自己的遗体,使我们能够开展这项研究,以改进失踪人员的搜寻工作。作者贡献 概念构思:Amber O. Brown、Darryl Hawker、Wentian Zhang、Steven Su、Maiken Ueland。数据管理:Amber O. Brown。形式分析:Amber O. Brown、Sandali Alahakone、Erin Lamb、Darryl Hawker、Maiken Ueland。资金获取:Maiken Ueland。调查研究:Amber O. Brown、Sandali Alahakone、Erin Lamb、Darryl Hawker、Maiken Ueland。方法学:Amber O. Brown、Taoping Liu、Wentian Zhang、Maiken Ueland。项目管理:Maiken Ueland。资源:Darryl Hawker、Wentian Zhang、Steven Su、Maiken Ueland。软件:Daniel Pasin、Taoping Liu。监督:Daniel Pasin、Darryl Hawker、Shari L. Forbes、Maiken Ueland。可视化:Daniel Pasin、Maiken Ueland。写作—初稿:Amber O. Brown。写作—审阅与编辑:Daniel Pasin、Taoping Liu、Wentian Zhang、Shari L. Forbes、Steven Su、Maiken Ueland。参考文献 1. Henderson M, Henderson P, Kiernan C. 失踪人员:发生率、问题与影响。报告编号:144。 2. Junkins EN, Carter DO. 人体遗骸、墓葬与沉积环境之间的关系。见:Schotsmans EMJ、Márquez‐Grant N、Forbes SL 主编。人体遗骸埋藏学:死者与沉积环境的法医学分析。第1版。Wiley;2017年。第143–54页。https://doi.org/10.1002/9781118953358.ch11 3. DeGreeff LE, Weakley-Jones B, Furton KG. 利用非接触式动态气流挥发性浓度技术制作人体遗骸探测犬训练辅助物。Forensic Sci Int. 2012;217(1–3):32–8. https://doi.org/10.1016/j.forsciint.2011.09.023 PMID: 22018852 4. Rendine M, Fiore C, Bertozzi G, De Carlo D, Filetti V, Fortarezza P, 等。腐败人体血液:犬类探测气味特征与挥发性有机化合物。J Forensic Sci. 2019;64(2):587–92. https://doi.org/10.1111/1556-4029.13901 PMID: 30176172 5. Cablk ME, Szelagowski EE, Sagebiel JC. 腐败动物遗骸顶空中挥发性有机化合物的表征,并与人体遗骸进行比较。Forensic Sci Int. 2012;220(1–3):118–25. https://doi.org/10.1016/j.forsciint.2012.02.007 PMID: 22424672 6. Stadler S, Focant J-F, Forbes SL. 土壤环境中腐败遗骸挥发性有机化合物的法医学分析。见:刑事与环境法医土壤学。Cham:Springer;2016年。第297–316页。https://doi.org/10.1007/978-3-319-33115-7 7. Rust L, Nizio KD, Forbes SL. 老化和表面类型对血液探测犬训练辅助物气味特征的影响。Anal Bioanal Chem. 2016;408(23):6349–60. https://doi.org/10.1007/s00216-016-9748-9 PMID: 27382970 8. Rebmann A, David E, Sorg MH, Song MH. 尸体犬手册:人体遗骸搜寻的法医训练与战术。Boca Raton, FL, USA:CRC Press Ltd;2000年。 9. Stefanuto PH, Rosier E, Tytgat J, Focant JF, Cuypers E. 腐败挥发性有机化合物的谱图分析。见:人体遗骸埋藏学:死者与沉积环境的法医学分析。Chichester, UK:John Wiley & Sons, Ltd;2017年。第39–52页。https://doi.org/10.1002/9781118953358.ch3 10. Rosier E, Loix S, Develter W, Van de Voorde W, Tytgat J, Cuypers E. 在腐败过程中寻找人类特异性挥发性标志物。PLoS One. 2015;10(9):e0137341. https://doi.org/10.1371/journal.pone.0137341 PMID: 26375029

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 16 / 17 11. Campobasso CP, Di Vella G, Introna F. 影响分解和双翅目定殖的因素。Forensic Sci Int. 2001;120(1–2):18–27. https://doi.org/10.1016/s0379-0738(01)00411-x PMID: 11457604 12. Martin C, Diederich C, Verheggen F. 尸体犬与死亡圣器——关于选择与训练程序的调查和文献综述。Animals (Basel). 2020;10(7):1219. https://doi.org/10.3390/ani10071219 PMID: 32709097 13. Lasseter AE, Jacobi KP, Farley R, Hensel L. 尸体犬与训导员团队在美国东南部寻回埋藏人类遗骸的能力。J Forensic Sci. 2003;48(3):617–21. https://doi.org/10.1520/jfs2002296 PMID: 12762533 14. Riezzo I, Neri M, Rendine M, Bellifemina A, Cantatore S, Fiore C, et al. 尸体犬:不科学的迷思还是可靠的生物装置?Forensic Sci Int. 2014;244:213–21. https://doi.org/10.1016/j.forsciint.2014.08.026 PMID: 25264919 15. Forbes SL, Perrault KA. 脊椎动物尸体周围空气和土壤中的分解气味谱分析。PLoS ONE. 2014;9:e95107. https://doi.org/10.1371/journal.pone.0095107 16. Perrault KA, Rai T, Stuart BH, Forbes SL. 使用全二维气相色谱-飞行时间质谱法对分解土壤中尸体挥发物的季节性比较。Anal Methods. 2015;7(2):690–8. https://doi.org/10.1039/c4ay02321h 17. Vass AA. 死亡气味。Forensic Sci Int. 2012;222(1–3):234–41. https://doi.org/10.1016/j.forsciint.2012.06.006 PMID: 22727573 18. Iqbal MA, Nizio KD, Ueland M, Forbes SL. 法医分解气味谱分析:实验设计与分析技术综述。TrAC Trends Anal Chem. 2017;91:112–24. https://doi.org/10.1016/j.trac.2017.04.009 19. Forbes SL, Perrault KA, Stefanuto P-H, Nizio KD, Focant J-F. 湿润中纬度(Cfb)气候下冬季和夏季分解VOC谱的比较。PLoS One. 2014;9(11):e113681. https://doi.org/10.1371/journal.pone.0113681 PMID: 25412504 20. Statheropoulos M, Agapiou A, Zorba E, Mikedi K, Karma S, Pallis GC, et al. 用于监测替代人体模型早期腐烂阶段的化学与光学联合方法。Forensic Sci Int. 2011;210(1–3):154–63. https://doi.org/10.1016/j.forsciint.2011.02.023 PMID: 21450424 21. Dubois LM, Perrault KA, Stefanuto P-H, Koschinski S, Edwards M, McGregor L, et al. 热脱附全二维气相色谱联用可变能量电子电离飞行时间质谱监测人血挥发性有机化合物谱的细微变化。J Chromatogr A. 2017;1501:117–27. https://doi.org/10.1016/j.chroma.2017.04.026 PMID: 28473200 22. Brown A, Lamb E, Deo A, Pasin D, Liu T, Zhang W, et al. 使用新型电子鼻技术为刑事调查定位失踪人员。iScience. 2023;26(4):106353. https://doi.org/10.1016/j.isci.2023.106353 PMID: 36994078 23. Karami H, Thurn B, de Boer NK, Ramos J, Covington JA, Lozano J, et al. 气体传感器技术在大规模灾难中定位遇难者的应用——综述。Nat Hazards. 2024;121(1):31–60. https://doi.org/10.1007/s11069-024-06809-5 24. Sunnucks EJ, Thurn B, Brown AO, Zhang W, Liu T, Forbes SL, et al. 新型电子鼻在大规模灾难后检测与饥饿或人体分解相关的挥发性有机化合物的性能。Sensors (Basel). 2024;24(18):5918. https://doi.org/10.3390/s24185918 PMID: 39338662 25. Thurn B, Deo A, Patel D, Sunnucks E, Forbes S, Stuart BH, et al. 用于灾难搜救的生前和死后人体挥发物。Forensic Chem. 2024;40:100596. https://doi.org/10.1016/j.forc.2024.100596 26. Rust L, Nizio KD, Wand MP, Forbes SL. 研究嗅探犬对衣物上残留血迹气味的检测限。Forensic Chemistry. 2018;9:62–75. https://doi.org/10.1016/j.forc.2018.05.002 27. Cablk ME, Sagebiel JC. 犬只定位单颗人类牙齿的现场能力。J Forensic Sci. 2011;56(4):1018–24. https://doi.org/10.1111/j.1556-4029.2011.01785.x PMID: 21554306 28. Furton K, Greb J, Holness H. 犬只与正交检测器指南科学工作组(SWGDOG)。2010;155. 29. Knobel Z, Ueland M, Nizio KD, Patel D, Forbes SL. 澳大利亚环境中人与猪分解速率和气味谱的比较。Aust J Forensic Sci. 2018;51(5):557–72. https://doi.org/10.1080/00450618.2018.1439100 30. Deo A, Forbes SL, Stuart BH, Ueland M. 澳大利亚温带环境中人类遗骸分解气味季节性变化的谱分析。Aust J Forensic Sci. 2019;52(6):654–64. https://doi.org/10.1080/00450618.2019.1637938 31. Forbes SL, Troobnikoff AN, Ueland M, Nizio KD, Perrault KA. 探测前后墓表分解气味的谱分析。Forensic Sci Int. 2016;259:193–9. https://doi.org/10.1016/j.forsciint.2015.12.038 PMID: 26773229 32. Ueland M, Harris S, Forbes SL. 检测挥发性有机化合物以在模拟倒塌建筑物中定位人类遗骸。Forensic Sci Int. 2021;323:110781. https://doi.org/10.1016/j.forsciint.2021.110781 PMID: 33878551 33. Clases D, Ueland M, Gonzalez De Vega R, Doble P, Pröfrock D. 通过GC-ICP-MS对人体尸体挥发性硫化合物的定量形态分析。Talanta. 2021;221:121424. https://doi.org/10.1016/j.talanta.2020.121424 34. Thurn B, Schotsmans EMJ, Ueland M. 石灰与气味:熟石灰对人类遗骸释放挥发物影响的初步研究。Forensic Sci Int. 2024;358:111745. https://doi.org/10.1016/j.forsciint.2023.111745 PMID: 37301722 35. McKinney W. Python中统计计算的数据结构。SciPy. 2010;445:51–6. 36. Virtanen P, Gommers R, Oliphant TE, Haberland M, Reddy T, Cournapeau D, et al. SciPy 1.0:Python科学计算的基础算法。Nat Methods. 2020;17(3):261–72. https://doi.org/10.1038/s41592-019-0686-2 PMID: 32015543 37. Negri LH. PeakUtils:一维数据的峰值检测工具。可从以下网址获取:https://bitbucket.org/lucashnegri/peakutils 38. Hunter JD. Matplotlib:二维图形环境。Comput Sci Eng. 2007;9:90–5. https://doi.org/10.1109/MCSE.2007.55

PLOS One | https://doi.org/10.1371/journal.pone.0360233 2026年10月21日 17 / 17 39. Waskom M. seaborn:统计数据可视化。JOSS. 2021;6(60):3021. https://doi.org/10.21105/joss.03021 40. Archer MS. 降雨和温度对暴露的新生儿遗体分解速率的影响。Sci Justice. 2004;44(1):35–41. https://doi.org/10.1016/S1355-0306(04)71683-4 PMID: 14964820 41. Vass AA. 难以捉摸的通用死后间隔公式。Forensic Sci Int. 2011;204(1–3):34–40. https://doi.org/10.1016/j.forsciint.2010.04.052 PMID: 20554133 42. Stefanuto PH, Perrault K, Grabherr S, Varlet V, Focant JF. 使用GC×GC-HRTOF-MS监测死后内部气体储库。Separations. 2016;3:24. https://doi.org/10.3390/separations3030024 43. Patel D, Dargan R, Burr WS, Daoust B, Forbes S. 使用全二维气相色谱鉴定停尸房环境中尸体的早期死后VOC谱。Separations. 2023;10(11):566. https://doi.org/10.3390/separations10110566 44. DeGreeff LE, Furton KG. 使用各种吸附材料通过非接触式动态气流采样和SPME-GC/MS收集和鉴定人体遗骸挥发物。Anal Bioanal Chem. 2011;401(4):1295–307. https://doi.org/10.1007/s00216-011-5167-0 PMID: 21695377 45. Martin C, Verheggen F. 面对死亡人人平等!——新鲜期人类尸体的挥发性尸胺类化合物特征。Forensic Chem. 2023;35:100516. https://doi.org/10.1016/j.forc.2023.100516 46. Dekeirsschieter J, Stefanuto P-H, Brasseur C, Haubruge E, Focant J-F. 通过全二维气相色谱-飞行时间质谱(GCxGC-TOFMS)增强对死亡气味的表征。PLoS One. 2012;7(6):e39005. https://doi.org/10.1371/journal.pone.0039005 PMID: 22723918

查看英文原文▾

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 1 / 17

OPEN ACCESS Citation: Brown AO, Alahakone S, Lamb E, Pasin D, Hawker D, Liu T, et al. (2026) A case study comparing the detection ability of cadaver detection dogs and electronic nose technology to a clandestine grave. PLoS One 21(10): e0360233. https://doi.org/10.1371/ journal.pone.0360233 Editor: Xiaoen Wei, Shuguang Hospital Affiliated to Shanghai University of Traditional Chinese Medicine, CHINA Received: June 3, 2026 Accepted: September 24, 2026 Published: October 21, 2026 Copyright: © 2026 Brown et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Data availability statement: The NOS.E data set and accompanying code, is available at github.com/Taphonomic-Analytical-Forensics/ nose-dogs. RESEARCH ARTICLE A case study comparing the detection ability of cadaver detection dogs and electronic nose technology to a clandestine grave Amber O. Brown 1,2 , Sandali Alahakone 1 , Erin Lamb 1 , Daniel Pasin 3 , Darryl Hawker 4 , Taoping Liu 5 , Wentian Zhang 6 , Shari L. Forbes 7 , Steven Su 8 , Maiken Ueland 1,6 * 1 Centre for Forensic Sciences, School of Mathematical and Physical Sciences, University of Technology Sydney, Sydney, New South Wales, Australia, 2 University of North Florida, Jacksonville, Florida, United States of America, 3 Hyperion Data, Griffith, New South Wales, Australia, 4 NSW Police Force Canine Unit, Parramatta, New South Wales, Australia, 5 School of Information Mechanics and Sensing Engineering, Xidian University, Xi’an, China, 6 School of Mathematical and Physical Science, University of Technology Sydney, Sydney, New South Wales, Australia, 7 Department of Chemistry and Biochemistry, University of Windsor, Windsor, Ontario, Canada, 8 College of Medical Information and AI, Shandong First Medical University, Jinan, Shandong, China * maiken.ueland@uts.edu.au Abstract Cadaver detection dogs (CDDs) are one of the best tools to locate clandestinely buried human remains. However, large data gaps exist in what VOC classes and concentrations are targeted by CDDs for detection. This study compared the alert responses produced by CDDs used by the New South Wales Police Force to responses generated by an electronic nose (named the NOS.E) with metal oxide sensors to a clandestine burial. For confirmatory analysis, VOC samples of the clandestine burial were taken, and compounds were identified using GC × GC-TOFMS. While statistical work was limited due to sample sizes, inferences were made about VOC presence and concentration to NOS.E and detection dog ability. Both CDDs and NOS.E were able to detect targeted chemical classes (sulfur and nitrogen containing compounds, alcohols, alkanes and aldehydes) which was supported by GC × GC-TOFMS. Correlation analyses demonstrated non-significant, but observational patterns that CDDs true positive alerts were associated with higher NOS.E responses to sulfur and nitrogen containing compounds, alcohols and alkanes. Additionally, a “no alert” or “False Positive” alert was associated with lower NOS.E responses. This work supports that it is both the presence and abundance of VOC chemical classes that influence true positive alerts from CDDs to buried human remains. 1. Introduction Locating long-term missing persons (missing longer than three months) [1] poses some of the most resource-intensive and challenging obstacles to law enforcement.

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 2 / 17 The first step of every missing person’s investigation is commencing physical searches in areas where the subject was last observed. If there is concern that the missing individual is deceased, law enforcement will incorporate methods for detecting and recovering human remains. When a body is exposed to the elements or left outdoors, remains can become scattered or buried due to environmental changes or animal activity. However, when a body is deliberately disposed of by someone attempting to conceal evidence of a crime, remains may be buried at various depths in sediment [2]. The recovery of these victims can be challenging with methods relying on visually locating remains (e.g., ground or aerial searches) and may require additional methods (e.g., detection of decomposition odor) for their location and retrieval. Cadaver detection dogs (CDDs) are currently one of the best tools to locate human remains that are obscured by environmental (i.e., soil, water and vegetation) factors. CDDs have a remarkable olfactory system [3–5] and are trained to detect the specific volatile organic compounds (VOCs) that are produced and emitted as a result of the breakdown of macromolecules (e.g., proteins, lipids and carbohydrates) during decomposition [6–8]. VOCs have a high vapor pressure and low molecular weight that allow for continuous emission into the environment [9,10] either endogenously through the victim, or exogenously from their perfumes, lotions or health products [11]. VOCs disperse through the environment from an area of high concentration (i.e., the “source”) to an area of low concentration. As these VOCs are dispersed continuously from a source, a “scent cone” is formed, whereby VOCs are more heavily concentrated in the air directly above the target and are diluted from the source due to environmental factors, such as wind [3]. Consequently, CDDs are able to detect trace VOCs from the edge of the scent cone and track the scent to the area where the VOCs are most concentrated [3,8,12–14]. Once CDDs locate the target, they will alert their handler through a trained behavior or signal. The detection of the scent cone by CDDs is complicated by buried remains, as soil composition and moisture content act as a sink, trapping VOCs and impacting scent cone dispersal [15,16]. To date, quantitative knowledge surrounding the types and concentrations of VOCs being dispersed from a scent cone are limited. The diffusion rate of each VOC differs due to specific chemical characteristics (e.g., size, polarity, stability and reactivity) and environmental conditions present at the time of dispersal. Furthermore, it is unknown how diffusion impacts the VOC profile of a scent cone from its source (i.e., an incomplete decomposition profile) and how diluted or incomplete decomposition profiles impact CDD efficacy. Current methods used to identify and quantify VOCs being produced from decomposing human remains rely on laboratory-based analytical techniques [10,15,17–21], though recent work has investigated the potential of using electronic noses (e-noses) for real-time detection of VOCs associated with human decomposition [22–24]. In addition, e-noses may be leveraged to provide insight into CDD detection ability and aid in training. In these cases, the e-nose could be deployed during training sessions to reduce false positive (reacting when there is no target) and negative (not reacting to a target) alerts of CDDs. Funding: MU is supported by an Australian Research Council Discovery Early Career Research Award (DE210100494). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. Competing interests: The authors have declared that no competing interests exist.

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 3 / 17 E-noses are portable, or semi portable, devices that mimic mammalian olfaction using multi-sensor (e.g., MOX) arrays. When the sensor comes into contact with target VOCs, the electrical resistance of the sensor is lowered, increasing the voltage of the current, generating quantitative signals that are impacted by the concentration of specific VOC classes. In an outdoor environment, the baseline response of the sensor is impacted by reference air naturally containing ambient VOCs. In order for an alert to be recorded, the target VOCs must be at a higher concentration than those found ambiently [23]. For scenarios where e-noses will be used to detect human remains, care must be taken in selecting MOX sensors, as the prevalence and abundance of targeted chemical classes change over the course of decomposition (i.e., “stages”). For robust detection, sensors targeting nitrogen-containing and sulfur-containing compounds as well as alcohols and aldehydes are a priority, as these are found in all stages of human decomposition [25]. To date, there is no standardized method for training and analyzing accuracy of CDDs in real world scenarios [7,12,26,27]. Furthermore, there is a distinct lack of data related to the detection ability of CDDs, including detection limits and quantitative analytical data relating to CDD efficiency and accuracy. For example, it is unknown whether it is the presence or concentration of specific VOCs that signal a CDD to alert. Despite years of research into the formation and emittance of decomposition VOCs, and the establishment of VOCs emitted at different stages of decomposition, little information exists as to which specific VOCs CDDs are targeting at specific timeframes to locate deceased individuals. It is currently unknown if singular VOCs are targeted, a combined VOC profile, or relative concentrations of specific VOCs or VOC classes are being tracked and are responsible for true positive CDD alerts. The lack of this information complicates training and evaluation of CDDs and has reduced CDD evidentiary capacity in court settings [28]. Both CDD training and search events and associated resources could be strengthened from secondary confirmation using e-nose technology to provide analytical support. This study aimed to compare the response given by NOS.E, an e-nose developed in house at the University of Technology Sydney (UTS) to the alerts of the CDDs used by the New South Wales Police Force (NSWPF) when locating a clandestine burial. Specifically, the study was set up so that the responses of an electronic nose could be compared to the responses of three certified CDDs over a single, buried deceased human. For analytical confirmation (i.e., identifying the chemical classes coming from buried remains), headspace from the buried remains were taken and analyzed via GC × GC-TOFMS (S1 Fig). The trial was set up to mimic a long-term missing person scenario, whereby the body was buried for approximately three months. 2. Materials and methods 2.1 Experimental site The study was undertaken at the Australian Facility for Taphonomic Experimental Research (AFTER) located in Western Sydney, NSW. The facility encompasses approximately 4.86 hectares of Cumberland dry sclerophyll forest owned by the UTS and complies with all ethical and legal requirements to conduct research on human cadavers (UTS HREC REF NO. ETH18–2999). The donor was acquired through the UTS Body Donation Program, managed by the Surgical and Anatomical Science Facility (SASF). In accordance with NSW Anatomy Act (1977) consent was provided by all donors to use their remains for the purpose of research at AFTER. The donor was a male, aged 79, weighing 75.2 kg at the time of death (20 th March 2020). Prior to placement, the body was stored in a cold storage facility. On the 25 th of March 2020, the donor (unclothed) was placed in a supine position in a grave approximately 60 cm deep. The grave was located over 200 m away from any other human remains at the facility. After the initial placement, the grave was left undisturbed for 98 days before sampling commenced to simulate a long-term clandestine grave, in order to follow the definition of a longterm missing person (i.e., over three months) [1]. The grave was sectioned into 6 regions: R1, R2, R3, R4, R5 and R6 (Fig 1). On occasions where the graves were probed (all days apart from the initial search on Day 98), 14 locations (Fig 1) within the grave were probed approximately 20–30 cm deep to allow air to escape. As quality control, and to ensure CDDs were not alerting to visual cues of disturbed soil as opposed to decomposition VOCs, three empty control graves were

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 4 / 17 also prepared on the day the donor was buried and probed in the same manner as the human grave. One empty grave was selected as the control for the chemical analysis (GC × GC-TOFMS and NOS.E). A Hobo Weather Station equipped with a Hobo U30 No Remote Communication (OneTemp pty ltd. Australia) data logger was used to monitor temperature (°C), solar radiation (W/m²), relative humidity (%), wind speed (m/s) wind direction and rainfall (mm) at an hourly rate. The aforementioned environmental parameters were all assessed in relation to NOS.E responses in each trial for both pre- and post-probe scenarios. 2.2 Cadaver detection dogs At the time of this study, three CDDs accredited with the NSWPF canine unit were used (Table 1). These dogs had previously been trained on human bone, decomposition fluid and decomposition fluid-stained clothing. Throughout the study, the number of dogs present during each sampling day varied due to the operational commitments of the CDDs and their handlers. This trial was set up as a single-blind study as conducting a double-blind study using the same grave sites was not possible and would remove the required handler expert oversight, resulting in challenges in recording dog responses. The study design followed standard training protocol by the NSWPF canine unit. During this work, three individual CDDs with three respective handlers that were blind to the location of the buried remains for the first trial were used. During each trial run, each CDD conducted the search independently and without guidance from their handler. The primary trainer was not blind to the grave location and supervised the CDD detection responses from afar to determine whether a definitive alert was presented. Alerts were recorded when the CDD entered the known GPS location of the grave and had an opportunity to alert. The alerts were defined as “True Positive”, where the CDD alerted to an area that had a NOS.E sensor response above baseline, “True Negative”, where the CDD did not alert to an area that did not have a NOS.E sensor response above baseline, “False Positive”, where the CDD alerted to an area that did not have a NOS.E sensor response above baseline, and “False Negative” where the CDD did not alert to an area where the NOS.E had a sensor response above baseline. All alerts were recorded (“True Positive”, “True Negative”, “False Positive”, and “False Negative”) after the confirmation from the expert opinion of the primary trainer as well as confirmatory NOS.E signal responses above baseline. The evaluation of the dogs was performed following animal ethics approval (ETH20–5205) . During the search events, each dog was taken into the site along the perimeter (the starting location differed between site visits), away from any existing donors on site, released off lead approximately 150 m from the grave site and was allowed to conduct a wide search of the area. The dogs were rewarded with a tennis ball (play reward) if they were able to correctly locate the grave as per their training. As sampling weeks continued, there was a chance that CDDs grew familiar Fig 1. Diagram of grave site with regions and probe location numbers. Six separate search days using both the CDDs and the NOS.E were conducted on 98, 105, 120, 126, 147 and 161-days postmortem. https://doi.org/10.1371/journal.pone.0360233.g001

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 5 / 17 with the area and the location of the grave. Therefore, in order to prevent false positive alerts, the dogs were let off leash from different directions each sampling event. If multiple dogs were present during a sampling event, there was a concern that a CDD may recognize another dog’s scent over the grave and make a false positive alert. To combat this, the handlers would guide the dogs over each of the three control graves once their run was completed to ensure that CDD scent was not concentrated in one location. The canine run order was also randomized each sampling time and there were breaks between the first dog and subsequent dog runs. Three control graves were selected to reduce CDD bias, but only one control grave was selected for analytical assessment to save resources. 2.3 Electronic nose (NOS.E) sampling The electronic nose (NOS.E) used in this study was developed in collaboration between the UTS Centre for Forensic Science and the UTS School for Biomedical Engineering. A total of 5 Tin Oxide Gas Sensor (TGS) metal oxide (MOX; Figaro, Japan) gas sensors (Table 2) were selected and configured based on previous human decomposition studies [22,25,29–34]. The sensors were specifically selected for human decomposition VOCs and the detection limits of the sensors configured in the NOS.E were previously established [24]. Sensors selected for this study targeted alcohols (Sensors 1, 2) and alkanes (Sensors 1–3) along with nitrogen and sulfur containing compounds (Sensors 4, 5). Sensor detection limits were not assessed due to the variability of the outdoor environment. However, positive and negative cross reactivities and VOC inhibition were addressed through baseline assessment and through establishing threshold criteria for peak assessment [22]. Prior to sampling, the NOS.E was turned on and allowed to ambiently sample the environment for 20 min to determine baseline sensor response to the environment. The NOS.E samples were taken prior to dog sampling trials, with constant air intake rate at max capacity (~1.1L/min) as in previous studies [22,24]. Samples were taken in a continuous manner while moving over the grave with the NOS.E air intake system hovering approximately 15 cm above ground, moving from R1 to R6 in numerical direction (1–13; Fig 1). A pre-set path was selected for consistency across sampling days and to ensure all grave regions were covered. Any sensor responses were recorded as time marks and response locations were transcribed on a map of the grave (Fig 1). The control grave located 5 m away from the experimental grave was also sampled on each trial day to compare NOS.E sensor responses. Environmental responses of the general site area were also recorded to ensure that any VOC presence were not due to the environment. Table 1. Summary of the biological and training information associated with each cadaver detection dog assessed at the time of the study. IDAge (years)BreedExperience at time of study (years)No. of Trials Present Dog 13English Springer SpanielApprox. 11/6 Dog 24Labrador RetrieverApprox. 24/6 Dog 37.5English Springer SpanielApprox. 64/6 https://doi.org/10.1371/journal.pone.0360233.t001 Table 2. NOS.E sensor configuration. SensorSensor nameTarget Gases 1TGS 2610 5UAlcohols/Alkanes 2TGS 2600Alcohols/Alkanes 3TGS 2612 5UAlkanes 4TGS 2603Sulfur/Nitrogen 5TGS 2602Nitrogen/Sulfur https://doi.org/10.1371/journal.pone.0360233.t002

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 6 / 17 The NOS.E data recordings were taken continuously by walking over the grave to emulate a search event. When a response from any sensor was observed above baseline, the sampling nozzle was held still until a maximum sensor response remained constant. This event was then recorded as a “hit”. Following the “hit”, the air-intake system was then moved away from the target and the sensors were allowed to return to baseline prior to recommencing sampling across the remaining grave. The NOS.E sampling protocol involved a series of wash steps between each sampling event to eliminate carryover or cross contamination (Table 3). An active VOC sampling time of 200 s per sequence was used and stitched together during data processing to cover the entire grave area. 2.4 NOS.E data processing The NOS.E (.txt) files were processed using a peak detection algorithm adapted from Brown et al. [22] to accommodate for multiple hits within the same file. This algorithm was intended to automate the calculation of peak heights. All detected peaks were reviewed by the authors to determine validity and inclusion in further analysis. This algorithm was developed using Python 3.7.12, pandas (1.3.5) [35], scipy (1.7.3) [36] and peakutils (1.3.5) [37] with data visualization using matplotlib (3.5.3) [38] and seaborn (0.12.2) [39]. The code, NOS.E data files and output files can be found at github.com/ Taphonomic-Analytical-Forensics/nose-dogs. Briefly, peaks (and hits) were automatically detected using the scipy.find_peaks function with a prominence value set to 0.025. This value was chosen based on a manual assessment of the resulting peak hits to ensure that there were no false negative readings. The normalized peak heights were determined by subtracting the baseline (determined using the peakutils.baseline function with default arguments) from the peak maxima. Peak heights were given as zero for sensors where the difference between the maximum and minimum sensor responses was less than 5% of the minimum response, or where there were no peaks using the peak detection algorithm. Peaks were also aligned across data files to correlate with the hits from the CDDs. To include the environmental data,.csv files were imported into Python and incorporated into the visualization of the NOS.E pre-and post-probing plots. An example of a sampling run showing all five sensor profiles with calculated peak heights can be found in S2 Fig. in the Supplementary Information. NOS.E sensor responses (Sensors 2–5; Sensor 1 was excluded as there was only one data point) were visually compared to CDD alert type using box-and-whisker plots and violin plots. The combination of low sample sizes and high variables gave this dataset low statistical power and limited rigorous statistical analysis. Spearman’s rank correlation (ρ) was selected to compare NOS.E sensor responses to alert types as an investigatory method. This method was selected as it is better suited for small sample sizes that are not normally distributed, are non-linear, and are monotropic, as observed in this dataset. Missing sensor values were imputed using k-nearest-neighbor (kNN) imputation, where (k = 5). Additionally, to determine whether statistical significance was present under multiple testing events, particularly due to low sample sizes, Benjamini-Hochberg (B-H) false discovery rate (FDR) adjustment was applied to p-values. Table 3. NOS.E sampling metrics during VOC sampling. Chamber Wash I100s Vacuum Time I10s Baseline Setup20s Vacuum Time II10s Sample Time200s Baseline Recovery100s Chamber Wash II100s https://doi.org/10.1371/journal.pone.0360233.t003

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 7 / 17 2.5 GC × GC-TOFMS sample collection VOC samples for laboratory analysis were collected concurrently with the dog trials and NOS.E sampling days. All samples were taken after probing, with the exception of day 98. Three replicate samples were collected from the headspace of both the test grave and control grave. A large aluminum hood was placed over each grave for 20 min to allow the VOCs to accumulate prior to being collected onto a dual sorbent tube containing Tenax TA and Carbograph 5TD (Markes International Ltd., UK; parts number C2-AAXX-5149). An ACTI-VOC™ low-flow pump (Markes International Ltd., UK) was used to actively sample VOCs for 10 min at a rate of 100 mL/min to collect a total volume of 1 L of headspace. Each tube was then wrapped in aluminum foil and transported in air-tight jars to the laboratory for analysis. Prior to sample analysis, each sorbent tube was injected with an internal standard of 0.2 μL of 10 ppm bromobenzene constituted in methanol (Sigma- Aldrich, Sydney, Australia) using an eVol® XR hand-held automated analytical syringe (SGE Analytical Science, Sydney, Australia). 2.6 GC × GC-TOFMS analysis Each sorbent tube underwent thermal desorption (TD) using a Markes Unity 2 Thermal Desorber (Markes International, Ltd, USA) and a Series 2 ULTRA multi-tube autosampler (Markes International, Ltd, USA). Each tube was desorbed at 300°C for 4 min, before being transferred to a general-purpose cold trap (TenaxTA/Carbograph 1TD) at a flow rate of 25 mL/min to a cold trap held at −15°C. The cold trap desorption was performed at 300°C for 4 min with a flow rate of 25 mL/min. Sample analysis was performed using a Pegasus 4D GC × GC-TOFMS (LECO, Castle Hill, NSW, Australia) connected to the TD unit using a 1 m uncoated fused-silica transfer line (Markes International Ltd.), heated to 120°C. The TD transfer line was joined to the primary column using an Ultimate Union kit (Agilent Technologies, Mulgrave, VIC, Australia). The primary column was a Rxi®-624Sil MS (30m x 0.250 mm id, 1.40 μm film thickness) and a Stabilwax® (2m x 0.250 mm id, 0.5μm film thickness) (Restek Corporation, Sydney, NSW, Australia) was used as the secondary column. A SilTite TM

μ-Union (SGE Analytical Science, Ringwood, VIC, Australia) was used to connect the primary and secondary columns. Helium was utilized as the system carrier gas and maintained at a constant flow rate of 1.0 mL/min. The primary oven was held at 35°C for 5 min before being increased to 240°C at a rate of 5°C/min and then held at 240°C for an additional 5 min, giving a total run time of 51 min. Modulator offset was set at 5°C with the secondary oven temperature offset at 15°C, with a modulation period of 5 s. The mass spectrometer transfer line was kept at 250°C and mass acquisition performed at a range between 29–450amu at 100 spectra/s. Ion source temperature was kept at 200°C and electron ionization energy at −70 eV with a 200 V offset detector voltage. 2.7 GC × GC-TOFMS data processing Data processing was performed using ChromaTOF® software (version 4.51.6.0, LECO, Australia). Baseline tracking was performed with an offset of 80% and automatic baseline smoothing, with a 150 signal-to-noise ratio. A 30 s peak width was used in the first dimension and a 0.15 s peak width was used in the second dimension. The National Institute of Standards and Technology (NIST, 2011) Mass Spectral Library was used with a minimum library match factor of 80% to establish a compound list. To perform compound alignment across samples, the samples were classed into their respective sampling day. All control samples were added to the same class. To be retained, analytes had to be present in 30% of the samples within a class or in two of the samples overall, due to the inherent differences expected between sampling days due to the decomposition process. Following initial data processing, the compound lists were exported into Microsoft Excel where known contaminants and instrument artefacts (column bleed, solvents, etc.) were removed. Replicate samples were averaged and blank subtraction was done using a 50% threshold whereby the analyte in the experimental samples had to be present in ≥

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 8 / 17 50% of the analyte response of the blank [22,31,34]. The remaining compounds were then sorted into their respective compound classes (alcohol, aldehyde, alkane, alkene, aromatic, ester, ether, halogenated, ketone, nitrogen containing, sulfur containing, or other). Data visualization was performed using Python 3.7.6 with seaborn (0.11.1) [39] and matplotlib (3.3.4) [38]. 3. Results and discussions 3.1 Environmental data The search trials commenced on Day 98 post burial (July 1 st , 2020), with the average daily temperature during the search days ranging from 9.1–13.7 ̊C, with a daily average temperature of 13.4 ̊C (Fig 2). This is reflective of an Australian (Sydney) winter, conditions where VOCs are less readily available than during warmer months [29,30]. A large period of heavy rainfall occurred between days 123–125 and between days 135–143 post-burial. 3.2 NOS.E data The results from the NOS.E were evaluated for each sampling day (Fig 3) and separated into categories of pre- and post- grave probing. NOS.E responses were recorded on all sampling days. The number and abundance of “hits” (defined as the number of times the NOS.E sensors produced a signal above baseline during the grave sampling) considered as positive responses were higher post-probing. This was expected, as the probing functions to release the VOCs from the burial environment [31], thereby making trapped VOCs available for dispersion and detection. Sensor 2, corresponding to alcohols and alkanes, and Sensor 5, corresponding to nitrogen and sulfur, were the most reactive throughout the trial and were the primary sensors which responded. From previous works, Sensor 5 has higher sensitivity to VOCs, reacting to concentrations 1.5–2 times lower than all other sensors present in the sensor array [24]. Sensor 3 (Alkanes) only reacted on days 126 and 161. Day 161 showed sensor responses from all NOS.E sensors, which were not reported on any other sampling day. On this day during the probing stage, the probe accidentally hit and punctured the buried remains. This resulted in the release of internally trapped VOCs that would not otherwise have been detected. These sensor responses, particularly that of Sensor 1, are therefore not likely to be indicative of VOCs present in a standard search scenario where Fig 2. Environmental data including average daily temperature (°C) and total daily rainfall (mm). https://doi.org/10.1371/journal.pone.0360233.g002

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 9 / 17 internal VOCs are contained within the remains and thus is not likely to be a primary sensor type for clandestine grave detection. The NOS.E recorded some sensor responses overtop of the control grave. This grave was located upwind and uphill of the buried donor, and 200 meters away from any other cadaver. Due to the location of the control grave, along with NOS.E sampling prior to dog trial runs, it is unlikely that these sensor responses are attributed to decomposition VOC contamination. A majority of responses were recorded from Sensor 5, detecting nitrogen and sulfur-containing compounds. As soil matrices are sinks in both the nitrogen and sulfur cycle, it is likely the sensor responses are attributed to environmental sources of nitrogen and sulfur. Interestingly, prior to probing, there was no noticeable effect on NOS.E sensor responses from any of the assessed environmental variables (temperature, solar radiation, relative humidity, wind speed, wind direction and rainfall). However, in post-probe scenarios, there was a potential correlation between temperature and increased sensor response for the NOS.E (Fig 3). The limited number of samples prevents statistical analyses of these observations. However, this observation differs to previous work where the NOS.E sensors were additionally influenced by gust speed and wind direction for detecting a human donor placed above ground [22]. It is likely that NOS.E performance differences may be attributed to human remains location (surface vs buried), time of year (summer versus winter) or VOC availability (freely available in air matrixes versus soil interference) which require further testing. 3.3 In-field search results As per the operating protocol of the NSWPF Canine Unit, each of the dogs were directed downwind of the buried donor in order to catch the edges of the scent cone and allowed to search independently for the clandestine grave. To minimize the chance of dogs relying on memory of the grave location rather than using the scent, the dogs were released from different areas of the site each trial day. Each dog alerted their handler by either laying down or barking to confirm their proposed detection of the buried remains. After probing events, all three dogs alerted at holes probed over the upper torso of the remains (Table 4; R1 and R2). Following this, the NOS.E also alerted with the highest sensor readings in this area, likely Fig 3. NOS.E sensor responses in relation to temperature changes over sampling days. (a) represents data taken pre-probing of the clandestine grave while (b) represents data taken post-probing and (c) represent readings taken from the control grave. Note: post-probing data was not collected on day 98. https://doi.org/10.1371/journal.pone.0360233.g003

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 10 / 17 due to the number and concentration of volatiles emitted from this region due to the presence of multiple decomposing organs [22]. As sampling weeks continued, the CDDs continued to alert at the same probed holes in regions R1 and R2 (Fig 1). During the trials where the grave was not re-probed, all three dogs either did not alert (Dog 2 and 3) or provided false positive alerts (Dog 1 and 2). After the graves were re-probed, all dogs were able to locate the grave with positive alerts (Table 4). Table 4. Cadaver detection dog alert responses and location compared to NOS.E above baseline response and location (reference Fig 1) in-field. N/A indicates that the dog was not a part of the trial for that sampling day. Canine trialNOS.E Trial Day PostmortemProbedCanineAlert Alert Classification* Location of AlertLocation of Alert D98NoDog 1N/AN/AN/AN/A Dog 2Ye sTrue PositiveR1, partial at R6R2, R6 Dog 3Ye sTrue PositiveR2, partial at R6 D105NoDog 1Ye sFalse Positive † R1/R2– Dog 2N/AN/AN/A Dog 3NoTrue Negative– Ye sDog 1Ye sTrue PositiveR1R2 (multiple hits), R4, R6 Dog 2N/AN/AN/A Dog 3Ye sTrue PositiveR3 D120NoDog 1N/AN/AN/AR3 Dog 2NoTrue Negative– Dog 3N/AN/AN/A Ye sDog 1N/AN/AN/AR3 Dog 2Ye sTrue PositiveR3 Dog 3N/AN/AN/A D126NoDog 1N/AN/AN/A– Dog 2NoTrue Negative– Dog 3NoTrue Negative– Ye sDog 1N/AN/AN/AR1 (multiple hits), R2, R3, R4 Dog 2Ye sTrue PositiveR1/R2 Dog 3Ye sTrue PositiveR1/R2 D147NoDog 1N/AN/AN/AR2 Dog 2N/AN/AN/A Dog 3NoFalse Negative– Ye sDog 1N/AN/AN/AR1, R2, R3 Dog 2N/AN/AN/A Dog 3Ye sTrue PositiveR4 D161NoDog 1N/AN/AN/A– Dog 2Ye sFalse Positive † – Dog 3N/AN/AN/A Ye sDog 1N/AN/AN/AR1, R2 Dog 2Ye sTrue PositiveR2 Dog 3N/AN/AN/A *Relative to NOS.E readings, † Alerted to handler. https://doi.org/10.1371/journal.pone.0360233.t004

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 11 / 17 The NOS.E was used to assess whether or not compounds were being emitted or if partial profiles were causing false positive alerts. On sampling Day 105, Dog 1 gave a false positive alert prior to probing. The NOS.E did not produce a signal to targeted volatiles in this region prior to probing (Table 4). Dog 3, who was also present during the trial, did not alert prior to probing on Day 105. Dog 3 has significantly more field experience than Dog 1 (Table 1), as Dog 1 only had one year of experience at the time of this study which likely attributed to the false positive alert. 3.4 GC×GC-TOFMS results Compounds identified from the GC × GC-TOFMS analysis were classified into chemical classes based on functional groups and were averaged per sampling day. The identified VOC classes included halogenated compounds, furans, esters, ethers, ketones, aldehydes, alcohols, alkanes, cycloalkanes, alkenes, nitrogen-containing compounds, sulfur- containing compounds, and aromatics (S1 Table). To allow for direct comparison with the NOS.E data, only compound classes that could be detected by the NOS.E sensors were further analyzed in this study. All of the selected VOC compound classes were detected throughout the entirety of the trial (Fig 4) with an increase in average peak area abundance observed on day 126 and further on day 147. These results were also supported by NOS.E (Fig 3). The increases were likely due to the rehydration of the remains following a period of rainfall which occurred just days before sampling, alongside an increase in the average temperature (Fig 2) which would have promoted decomposition [40,41] resulting in an increase in VOC production. Nitrogen containing compounds were detected in higher quantities on days 98 and 147. Sulfur containing compounds also peaked on sampling day 147. However, on the majority of the trial days, alcohol and alkanes were the main contributors to the VOC profiles. Interestingly, Sensor 5 (nitrogen and sulfur containing compounds) had the highest response of all NOS.E sensors across the sampling days, which does not align directly with VOC data. This is likely due to the sensitivity and response profile (i.e., log response curve) of Sensor 5, as reported previously [24]. Sulfur containing compounds Fig 4. VOC Abundance as peak area (n = 3) summed and averaged from the clandestine burial site over the sampling period. Burial was probed for all days except day 98. Note, only those compound classes detectable by the NOS.E sensors are shown. https://doi.org/10.1371/journal.pone.0360233.g004

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 12 / 17 are the most widely recognized group detected in decomposition odor [10,17,32,34,42–45]. In this study, dimethyl disulfide (DMDS) was the most consistently observed polysulfide (S1 Table). Several nitrogen containing compounds, commonly found during the early stages of decomposition [6,46], were also detected across sampling days (Fig 4 and S1 Table) but similarly to the sulfur compounds, they appeared in very low abundance during the GC × GC-TOFMS analysis. Alcohols were found to increase during the study and dramatically spiking at Day 147 before rapidly declining on Day 161 (Fig 4). Alkanes followed a similar trend to alcohols, however there was a noticeable decrease in abundance on Day 120. 3.5 NOS.E and CDD comparison NOS.E sensor “hits” were compared to CDD alert responses. There were no false positive alerts from the most experienced dog (Dog 3; Table 4). Additionally, false positive alerts only occurred at times when the grave was not probed (Table 4). Violin plots of all five sensor responses were conducted to compare with alert responses between CDDs that had multiple trials (Fig 5a and 5b). The distribution of true positive hits compared to sensor type response demonstrated that one CDD (Fig 5a) had a wider distribution of true positive alerts in comparison to the CDD that was present at multiple trials (Fig 5b). Additionally, one dog had more resolute alerts when higher concentrations of sulfur or nitrogen containing compounds were present. This may be an artifact of individual differences, breed differences (English Springer Spaniel versus Labrador retriever), or experience (6 years versus 2 years). Both the NOS.E and VOC data demonstrate that the increase in abundance of sulfur and nitrogen containing compounds post-probing may have contributed to Dog 2 correctly producing a true positive alert. The violin plots indicate that the collective response of Sensors 2 (Alcohols/ Alkanes), 4 (Sulfur/Nitrogen), and 5 (Nitrogen/Sulfur) are more important for accurate detection than Sensors 1 (Alcohols/Alkanes) and 3 (Alkanes). Observationally, it appears that there is a threshold for discerning human remain VOCs from environmental sulfur, (Sensor 5 (Nitrogen/Sulfur)), as low sensor responses were detected on no alert areas. However, once the sensor response was above a certain peak height, the response aided the dogs in providing true positive alerts. Supporting this, the false positive alert for Dog 2 demonstrated a similar Sensor 5 response to the “No Alert”, but none of the other sensor responses. This assessment is further supported when comparing NOS.E sensor responses to all dog alert types (including Dog 1; Figs 6 and 7). It appears that it is both the presence and threshold of VOC concentration classes that influence true alerts from CDDs to buried human remains. Fig 5. Violin plots of cadaver detection dog (CDD) alerts for CDD 2 (a) and CDD 3 (b). Each sampling point represents a recorded alert. “NoA” represents “no alert”, “TP” represents “True Positive”, “PA” represents “partial alert” and “FP” represents “False Positive.” No “FP” data were recorded by CDD 3. https://doi.org/10.1371/journal.pone.0360233.g005

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 13 / 17 Computed Spearman’s rank (ρ) correlations across kNN imputed sensor responses did not show any statistically significant associations between response type and NOS.E sensor response value after controlling for false discovery rate (BH-adjusted p-values). Observationally, ρ values demonstrated positive monotonic associations between true positive Fig 6. Box and Whisker plots of combined cadaver detection dog (CDD) alerts to the clandestine grave. Each sampling point represents a recorded alert from each location (R1-13) where both the CDD and the NOS.E alerted. “FP” represents “False Positive.”, “NoA” represents “no alert”, “PA” represents “partial alert” and “TP” represents “True Positive”. https://doi.org/10.1371/journal.pone.0360233.g006 Fig 7. Spearman’s rank (ρ) correlations after kNN imputed data and BH corrections across sensor values and cadaver detection dog (CDD) alert type. “FP” represents “False Positive.”, “NoA” represents “no alert”, “PA” represents “partial alert” and “TP” represents “True Positive”. Tile colors represent the sign and magnitude of ρ using a diverging scale, where red represents a positive association and blue represents a negative association. https://doi.org/10.1371/journal.pone.0360233.g007

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 14 / 17 alerts and sensor value, while no alerts and false positive demonstrated negative associations. Namely, true positive alerts tended to increase across all higher sensor values, whereas no alerts and false positives decreased as sensor values increased. Partial alerts reflected a mixed pattern to all sensors. However, as these values were not statistically significant, caution should be taken in interpretation. 4. Conclusions This work provided novel insight into how VOC class and concentration impact CDD detection capability in terms of alert responses. Specifically, this work helped discern which VOC compound classes were relevant for true response alerts from CDDs, as well as provided insight into which VOC classes and concentrations were less likely to cause confident responses for CDDs in detecting human remains in a buried environment. Prior to this study, none of the CDDs had exposure to buried human remains. This study was limited, as only one donor could be assessed, and VOC variability associated with age, sex, body mass index, and other environmental factors, such as soil composition, could not be adequately or statistically assessed. However, this pilot work was beneficial in understanding CDD capabilities that have been developed with their current training protocols and forms a foundation for future work incorporating multiple donors and larger-scale studies. The NOS.E provided similar sensor responses to CDDs, which was later supported by analytical VOC data. As in previous works, the presence of sulfur and nitrogen containing compounds are critical for CDD true positive alerts. This study helped demonstrate that concentration of sulfur and nitrogen containing compounds play a role in true detections. It was determined that probing the grave increased the detection ability of the NOS.E (Fig 5) both in terms of compound class detection and intensity of the hit. Probing the grave also increased the detection accuracy of less experienced CDDs, whereby after probing there were no false positive or false negative alerts (Table 4). Some variables were unavoidable or uncontrollable in this study, due to the working commitments of the police and the CDDs. For example, there were varying numbers of field tests per dog. Despite alternating schedules, days between trials and alternating the order in which the CDDs searched, there is a potential that the CDDs became familiar with the location of the grave. Therefore, caution should be taken with interpreting lower VOC threshold values for more experienced dogs. However, as there were no false negative alerts after probing, this demonstrates that CDD alerts were more likely due to a change in the scent picture than location memory. To further support this, additional studies with more donor sites concurrently would be beneficial. Additionally, in order to be field-deployable, additional forensic testing and validation, including sensor detection limits, responses to various soil types and burial depths, and comparisons to mixed odors will need to be conducted. Despite the study limitations, having concurrent analytical data as to what and if the dogs are detecting human decomposition VOCs, is useful in the further training of current and new cadaver detection dogs. Supporting information S1 Fig. Flow chart depicting the study objective and methods that were compared. (PDF) S2 Fig. Example sampling run of the grave on day 161 post-probing. The red line is the calculated baseline with the vertical black line the distance from the baseline to the peak maximum. (PDF) S1 Table. Showing the individually tentatively identified VOCs of the experimental grave per sampling day. Only VOCs that were present in three or more sampling days are presented here. (PDF)

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 15 / 17 Acknowledgments The authors would like to thank the NSW Police Force canine unit handlers, and their dogs; Wags, Tilly and Bryson who participated in this study. Their time and experience were invaluable to the work. The authors would also like to thank our donors for their altruistic gift of donating their body in death which allows us to undertake this research to improve the detection of missing persons. Author contributions Conceptualization: Amber O. Brown, Darryl Hawker, Wentian Zhang, Steven Su, Maiken Ueland. Data curation: Amber O. Brown. Formal analysis: Amber O. Brown, Sandali Alahakone, Erin Lamb, Darryl Hawker, Maiken Ueland. Funding acquisition: Maiken Ueland. Investigation: Amber O. Brown, Sandali Alahakone, Erin Lamb, Darryl Hawker, Maiken Ueland. Methodology: Amber O. Brown, Taoping Liu, Wentian Zhang, Maiken Ueland. Project administration: Maiken Ueland. Resources: Darryl Hawker, Wentian Zhang, Steven Su, Maiken Ueland. Software: Daniel Pasin, Taoping Liu. Supervision: Daniel Pasin, Darryl Hawker, Shari L. Forbes, Maiken Ueland. Visualization: Daniel Pasin, Maiken Ueland. Writing – original draft: Amber O. Brown. Writing – review & editing: Daniel Pasin, Taoping Liu, Wentian Zhang, Shari L. Forbes, Steven Su, Maiken Ueland. References 1. Henderson M, Henderson P, Kiernan C. Missing persons: Incidence, issues and impacts. Report No.: 144. 2. Junkins EN, Carter DO. Relationships between human remains, graves and the depositional environment. In: Schotsmans EMJ, Márquez‐Grant N, Forbes SL, editors. Taphonomy of human remains: Forensic analysis of the dead and the depositional environment. 1st ed. Wiley; 2017. p. 143–54. https://doi.org/10.1002/9781118953358.ch11 3. DeGreeff LE, Weakley-Jones B, Furton KG. Creation of training aids for human remains detection canines utilizing a non-contact, dynamic airflow volatile concentration technique. Forensic Sci Int. 2012;217(1–3):32–8. https://doi.org/10.1016/j.forsciint.2011.09.023 PMID: 22018852 4. Rendine M, Fiore C, Bertozzi G, De Carlo D, Filetti V, Fortarezza P, et al. Decomposing human blood: Canine detection odor signature and volatile organic compounds. J Forensic Sci. 2019;64(2):587–92. https://doi.org/10.1111/1556-4029.13901 PMID: 30176172 5. Cablk ME, Szelagowski EE, Sagebiel JC. Characterization of the volatile organic compounds present in the headspace of decomposing animal remains, and compared with human remains. Forensic Sci Int. 2012;220(1–3):118–25. https://doi.org/10.1016/j.forsciint.2012.02.007 PMID: 22424672 6. Stadler S, Focant J-F, Forbes SL. Forensic analysis of volatile organic compounds from decomposed remains in a soil environment. In: Soil in criminal and environmental forensics. Cham: Springer; 2016. p. 297–316. https://doi.org/10.1007/978-3-319-33115-7 7. Rust L, Nizio KD, Forbes SL. The influence of ageing and surface type on the odour profile of blood-detection dog training aids. Anal Bioanal Chem. 2016;408(23):6349–60. https://doi.org/10.1007/s00216-016-9748-9 PMID: 27382970 8. Rebmann A, David E, Sorg MH, Song MH. Cadaver dog handbook: Forensic training and tactics for the recovery of human remains. Boca Raton, FL, USA: CRC Press Ltd; 2000. 9. Stefanuto PH, Rosier E, Tytgat J, Focant JF, Cuypers E. Profiling volatile organic compounds of decomposition. In: Taphonomy of human remains: Forensic analysis of the dead and the depositional environment. Chichester, UK: John Wiley & Sons, Ltd; 2017. p. 39–52. https://doi. org/10.1002/9781118953358.ch3 10. Rosier E, Loix S, Develter W, Van de Voorde W, Tytgat J, Cuypers E. The search for a volatile human specific marker in the decomposition process. PLoS One. 2015;10(9):e0137341. https://doi.org/10.1371/journal.pone.0137341 PMID: 26375029

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 16 / 17 11. Campobasso CP, Di Vella G, Introna F. Factors affecting decomposition and Diptera colonization. Forensic Sci Int. 2001;120(1–2):18–27. https:// doi.org/10.1016/s0379-0738(01)00411-x PMID: 11457604 12. Martin C, Diederich C, Verheggen F. Cadaver dogs and the deathly hallows-a survey and literature review on selection and training procedure. Animals (Basel). 2020;10(7):1219. https://doi.org/10.3390/ani10071219 PMID: 32709097 13. Lasseter AE, Jacobi KP, Farley R, Hensel L. Cadaver dog and handler team capabilities in the recovery of buried human remains in the southeastern United States. J Forensic Sci. 2003;48(3):617–21. https://doi.org/10.1520/jfs2002296 PMID: 12762533 14. Riezzo I, Neri M, Rendine M, Bellifemina A, Cantatore S, Fiore C, et al. Cadaver dogs: Unscientific myth or reliable biological devices? Forensic Sci Int. 2014;244:213–21. https://doi.org/10.1016/j.forsciint.2014.08.026 PMID: 25264919 15. Forbes SL, Perrault KA. Decomposition odour profiling in the air and soil surrounding vertebrate carrion. PLoS ONE. 2014;9:e95107. https://doi. org/10.1371/journal.pone.0095107 16. Perrault KA, Rai T, Stuart BH, Forbes SL. Seasonal comparison of carrion volatiles in decomposition soil using comprehensive two-dimensional gas chromatography – time of flight mass spectrometry. Anal Methods. 2015;7(2):690–8. https://doi.org/10.1039/c4ay02321h 17. Vass AA. Odor mortis. Forensic Sci Int. 2012;222(1–3):234–41. https://doi.org/10.1016/j.forsciint.2012.06.006 PMID: 22727573 18. Iqbal MA, Nizio KD, Ueland M, Forbes SL. Forensic decomposition odour profiling: A review of experimental designs and analytical techniques. TrAC Trends Anal Chem. 2017;91:112–24. https://doi.org/10.1016/j.trac.2017.04.009 19. Forbes SL, Perrault KA, Stefanuto P-H, Nizio KD, Focant J-F. Comparison of the decomposition VOC profile during winter and summer in a moist, mid-latitude (Cfb) climate. PLoS One. 2014;9(11):e113681. https://doi.org/10.1371/journal.pone.0113681 PMID: 25412504 20. Statheropoulos M, Agapiou A, Zorba E, Mikedi K, Karma S, Pallis GC, et al. Combined chemical and optical methods for monitoring the early decay stages of surrogate human models. Forensic Sci Int. 2011;210(1–3):154–63. https://doi.org/10.1016/j.forsciint.2011.02.023 PMID: 21450424 21. Dubois LM, Perrault KA, Stefanuto P-H, Koschinski S, Edwards M, McGregor L, et al. Thermal desorption comprehensive two-dimensional gas chromatography coupled to variable-energy electron ionization time-of-flight mass spectrometry for monitoring subtle changes in volatile organic compound profiles of human blood. J Chromatogr A. 2017;1501:117–27. https://doi.org/10.1016/j.chroma.2017.04.026 PMID: 28473200 22. Brown A, Lamb E, Deo A, Pasin D, Liu T, Zhang W, et al. The use of novel electronic nose technology to locate missing persons for criminal investigations. iScience. 2023;26(4):106353. https://doi.org/10.1016/j.isci.2023.106353 PMID: 36994078 23. Karami H, Thurn B, de Boer NK, Ramos J, Covington JA, Lozano J, et al. Application of gas sensor technology to locate victims in mass disasters – a review. Nat Hazards. 2024;121(1):31–60. https://doi.org/10.1007/s11069-024-06809-5 24. Sunnucks EJ, Thurn B, Brown AO, Zhang W, Liu T, Forbes SL, et al. Performance of a novel electronic nose for the detection of volatile organic compounds relating to starvation or human decomposition post-mass disaster. Sensors (Basel). 2024;24(18):5918. https://doi.org/10.3390/ s24185918 PMID: 39338662 25. Thurn B, Deo A, Patel D, Sunnucks E, Forbes S, Stuart BH, et al. Ante- and post-mortem human volatiles for disaster search and rescue. Forensic Chem. 2024;40:100596. https://doi.org/10.1016/j.forc.2024.100596 26. Rust L, Nizio KD, Wand MP, Forbes SL. Investigating the detection limits of scent-detection dogs to residual blood odour on clothing. Forensic Chemistry. 2018;9:62–75. https://doi.org/10.1016/j.forc.2018.05.002 27. Cablk ME, Sagebiel JC. Field capability of dogs to locate individual human teeth. J Forensic Sci. 2011;56(4):1018–24. https://doi.org/10.1111/ j.1556-4029.2011.01785.x PMID: 21554306 28. Furton K, Greb J, Holness H. The scientific working group on dog and orthogonal detector guidelines (SWGDOG). 2010;155. 29. Knobel Z, Ueland M, Nizio KD, Patel D, Forbes SL. A comparison of human and pig decomposition rates and odour profiles in an Australian environment. Aust J Forensic Sci. 2018;51(5):557–72. https://doi.org/10.1080/00450618.2018.1439100 30. Deo A, Forbes SL, Stuart BH, Ueland M. Profiling the seasonal variability of decomposition odour from human remains in a temperate Australian environment. Aust J Forensic Sci. 2019;52(6):654–64. https://doi.org/10.1080/00450618.2019.1637938 31. Forbes SL, Troobnikoff AN, Ueland M, Nizio KD, Perrault KA. Profiling the decomposition odour at the grave surface before and after probing. Forensic Sci Int. 2016;259:193–9. https://doi.org/10.1016/j.forsciint.2015.12.038 PMID: 26773229 32. Ueland M, Harris S, Forbes SL. Detecting volatile organic compounds to locate human remains in a simulated collapsed building. Forensic Sci Int. 2021;323:110781. https://doi.org/10.1016/j.forsciint.2021.110781 PMID: 33878551 33. Clases D, Ueland M, Gonzalez De Vega R, Doble P, Pröfrock D. Quantitative speciation of volatile sulphur compounds from human cadavers by GC-ICP-MS. Talanta. 2021;221:121424. https://doi.org/10.1016/j.talanta.2020.121424 34. Thurn B, Schotsmans EMJ, Ueland M. Lime and odour: A preliminary investigation into the effect of hydrated lime on the volatiles emitted from human remains. Forensic Sci Int. 2024;358:111745. https://doi.org/10.1016/j.forsciint.2023.111745 PMID: 37301722 35. McKinney W. Data structures for statistical computing in Python. SciPy. 2010;445:51–6. 36. Virtanen P, Gommers R, Oliphant TE, Haberland M, Reddy T, Cournapeau D, et al. SciPy 1.0: Fundamental algorithms for scientific computing in Python. Nat Methods. 2020;17(3):261–72. https://doi.org/10.1038/s41592-019-0686-2 PMID: 32015543 37. Negri LH. PeakUtils: Peak detection utilities for 1D data. Available from: https://bitbucket.org/lucashnegri/peakutils 38. Hunter JD. Matplotlib: A 2D graphics environment. Comput Sci Eng. 2007;9:90–5. https://doi.org/10.1109/MCSE.2007.55

PLOS One | https://doi.org/10.1371/journal.pone.0360233 October 21, 2026 17 / 17 39. Waskom M. seaborn: Statistical data visualization. JOSS. 2021;6(60):3021. https://doi.org/10.21105/joss.03021 40. Archer MS. Rainfall and temperature effects on the decomposition rate of exposed neonatal remains. Sci Justice. 2004;44(1):35–41. https://doi. org/10.1016/S1355-0306(04)71683-4 PMID: 14964820 41. Vass AA. The elusive universal post-mortem interval formula. Forensic Sci Int. 2011;204(1–3):34–40. https://doi.org/10.1016/j.forsciint.2010.04.052 PMID: 20554133 42. Stefanuto PH, Perrault K, Grabherr S, Varlet V, Focant JF. Postmortem internal gas reservoir monitoring using GC×GC-HRTOF-MS. Separations. 2016;3:24. https://doi.org/10.3390/separations3030024 43. Patel D, Dargan R, Burr WS, Daoust B, Forbes S. Identifying the early post-mortem VOC profile from cadavers in a morgue environment using comprehensive two-dimensional gas chromatography. Separations. 2023;10(11):566. https://doi.org/10.3390/separations10110566 44. DeGreeff LE, Furton KG. Collection and identification of human remains volatiles by non-contact, dynamic airflow sampling and SPME-GC/MS using various sorbent materials. Anal Bioanal Chem. 2011;401(4):1295–307. https://doi.org/10.1007/s00216-011-5167-0 PMID: 21695377 45. Martin C, Verheggen F. All equal in the face of death! – Characterization of the volatile cadaveric compounds of fresh stage human corpses. Forensic Chem. 2023;35:100516. https://doi.org/10.1016/j.forc.2023.100516 46. Dekeirsschieter J, Stefanuto P-H, Brasseur C, Haubruge E, Focant J-F. Enhanced characterization of the smell of death by comprehensive two- dimensional gas chromatography-time-of-flight mass spectrometry (GCxGC-TOFMS). PLoS One. 2012;7(6):e39005. https://doi.org/10.1371/journal.pone.0039005 PMID: 22723918

本文为开放获取(Open Access)文章,全文副本经 Unpaywall 定位转载,遵循原许可协议(Open Access (cc-by, via Unpaywall)); 来源:PloS one · DOI: 10.1371/journal.pone.0360233,版权归原作者及出版方所有;中文为机器翻译,临床术语以英文原文为准。 查看原文 ↗

跳转原文 ↗ 返回列表

快捷键 S 一键收藏本文,收藏内容在 我的收藏 查看;PubMed 位于境外,直接访问原文可能需要国际网络环境,站内摘要无需翻墙即可阅读。

采集时间:2026-10-24 06:52:59 · 中文解读将在编辑审核后另行发布,未经审核的自动标注不构成临床依据。